Slant/Fin Boiler Victory VSPH series POWER LED flashing

What this problem usually means

On the Victory VSPH integrated boiler control, a flashing POWER LED by itself is a control lockout indicating the 120 V power supply polarity is reversed. The manual's remedy is direct: reverse the hot and neutral wires in the junction box. The boiler will not run correctly on reversed polarity.

Likely causes

  1. 120 V power supply polarity reversed
  2. Hot and neutral wires reversed in the junction box

How to fix it — step by step

  1. Record the code before resetting anything: write down the display exactly as shown (POWER LED flashing) and whether the boiler was in a heating call, a hot-water call, or idle when it appeared.
  2. Safety: turn the thermostat down, switch off power to the boiler at the service switch and breaker, and close the manual gas shutoff if you smell gas or see scorching. Do not open the burner compartment if you smell gas; leave and call the gas supplier.
  3. Locate the part: the junction box is on the boiler where the 120 V supply lands; the integrated boiler control with its five LEDs is behind the jacket front panel.
  4. Test: verify polarity at the junction box with a meter or polarity tester. Reversed hot and neutral confirms the code's cause; correct polarity with the code still set means re-check which LEDs are actually flashing against the manual's table.
  5. End at the fix: switch power off, reverse the hot and neutral wires in the junction box, restore power, and confirm the POWER LED is steady and the boiler runs a normal cycle. Electrical work is technician work.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.

Related Slant/Fin Boiler Victory VSPH series problems

See all Slant/Fin Victory VSPH series codes & guides →