4 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Four flashes means hot surface ignitor failure. The manual's causes are the ignitor's electrical wiring, a broken ignitor tip or ceramic insulator, and a defective ignitor that does not glow properly. Without a working ignitor there is no ignition trial at all.
Likely causes
- Ignitor wiring fault
- Ignitor tip or ceramic insulator broken
- Defective hot surface ignitor
How to fix it — step by step
- Record the code before resetting anything: write down the display exactly as shown (4 flashes) and whether the boiler was in a heating call, a hot-water call, or idle when it appeared.
- Safety: turn the thermostat down, switch off power to the boiler at the service switch and breaker, and close the manual gas shutoff if you smell gas or see scorching. Do not open the burner compartment if you smell gas; leave and call the gas supplier.
- Locate the part: the hot surface ignitor is at the burner, reached by removing it per the manual's How To Do It procedure; its leads run back to the control board.
- Test: check the wire connections from the ignitor, then remove the ignitor with power off and inspect for cracks or breakage. The manual's live test: energize the removed ignitor (with the gas valve turned off so no gas can exit the opening) and observe the glow; a tip that does not glow quickly and strongly is defective. Keep hands and objects clear of the hot tip.
- End at the pinpoint: tighten the wiring or replace the Ignitor (same manufacturer, model, and length) as the inspection and glow test condemn. Technician work.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Hot surface ignitor.
Parts that commonly fix it
- Hot surface ignitorShop at Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.