Slant/Fin Boiler Prodigy 21 (KC-50/KC-100) Steady on

What this problem usually means

A steady-on Prodigy 21 diagnostic LED means loss of flame signal: the flame signal was lost after a proper flame signal had been established. The manual notes the boiler continues to run normally but only at high fire. Its causes are an improper air-gas ratio at low fire, low blower speed at low fire, and a bad flame sensor.

Likely causes

  1. Flame signal lost after being established
  2. Improper air-gas ratio at low fire
  3. Blower speed too low at low fire
  4. Bad flame sensor

How to fix it — step by step

  1. Record the code before resetting anything: write down the display exactly as shown (Steady on) and whether the boiler was in a heating call, a hot-water call, or idle when it appeared.
  2. Safety: turn the thermostat down, switch off power to the boiler at the service switch and breaker, and close the manual gas shutoff if you smell gas or see scorching. Do not open the burner compartment if you smell gas; leave and call the gas supplier.
  3. Locate the part: the flame sensor at the burner and its current jack on the electronic board; the gas valve and blower calibration points are covered in the manual's Operation Procedures.
  4. Test: check the flame current at low fire with a microampmeter at the board's jack (at least 1 microamp needed, typically 5 to 10), then check the gas valve calibration and the blower calibration at low fire. A weak current with correct calibrations sends you to the No Ignition flame sensing checks for the sensor itself.
  5. End at the pinpoint: adjust the Gas valve at low fire, adjust blower speed, or repair/replace the Flame sensor, as the measurements condemn. Technician work. → Shop the flame sensor at Amazon

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $10–$355

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.

Related Slant/Fin Boiler Prodigy 21 (KC-50/KC-100) problems

See all Slant/Fin Prodigy 21 (KC-50/KC-100) codes & guides →