Slant/Fin Boiler Prodigy 21 (KC-50/KC-100) 6 flashes

What it should look like on your machine

then it repeats

6 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Six flashes means the low water cutoff is open. The manual's test set is shared with the high limit checks: a defective high limit, a boiler water level that is too low, a circulator not running, and zone valves not opening. In plain terms the boiler is being told it does not have safe water conditions to fire.

Likely causes

  1. Low water cutoff open
  2. Boiler water level too low
  3. Defective high limit
  4. Circulator not running
  5. Zone valves not opening

How to fix it — step by step

  1. Record the code before resetting anything: write down the display exactly as shown (6 flashes) and whether the boiler was in a heating call, a hot-water call, or idle when it appeared.
  2. Safety: turn the thermostat down, switch off power to the boiler at the service switch and breaker, and close the manual gas shutoff if you smell gas or see scorching. Do not open the burner compartment if you smell gas; leave and call the gas supplier.
  3. Locate the part: the low water cutoff is on the boiler piping; check the temperature/pressure gauge on the boiler for the water level evidence, and the pressure regulator (feed valve) on the fill line.
  4. Test: read the gauge pressure, then carefully snap open the relief valve handle to determine whether the boiler is full of water, per the manual. If it is not full, check for system leaks and check the water pressure regulator operation. Also run the manual's high limit continuity test (set the limit to 180 F, run the water above it, contacts should open; contacts still closed above 180 F condemn the limit) and prove the circulator and zone valves get power and move.
  5. End at the pinpoint: repair leaks and adjust or replace the Pressure regulator to restore water level, or replace the High limit, Circulator, or Zone valve as condemned. Technician work.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.