Slant/Fin Boiler Prodigy 21 (KC-50/KC-100) 2 flashes
What it should look like on your machine
then it repeats
2 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Two flashes means no ignition: no flame signal after the trial for ignition. The manual's cause list runs from no gas supply to the valve or burner, through wrong air-gas ratio and wrong orifice sizing, to loose or reversed electrical connections and a weak or defective flame sensor.
Likely causes
- No gas supply to the gas valve or burner
- Air-gas ratio not proper
- Orifice sizing not correct
- Loose or reversed electrical connections
- Flame sensor current weak (below 1 microamp)
- Defective flame sensor
How to fix it — step by step
- Record the code before resetting anything: write down the display exactly as shown (2 flashes) and whether the boiler was in a heating call, a hot-water call, or idle when it appeared.
- Safety: turn the thermostat down, switch off power to the boiler at the service switch and breaker, and close the manual gas shutoff if you smell gas or see scorching. Do not open the burner compartment if you smell gas; leave and call the gas supplier.
- Locate the part: the gas valve and its LED on the control board, the flame sensor at the burner, and the manual gas shutoff in the gas line to the boiler.
- Test: confirm the manual shutoff is open and gas pressure reaches the valve, check the gas valve LED and outlet pressure to prove the valve opens, then measure flame sensor current with a microampmeter at the board's flame current jack. The manual's numbers: at least 1 microamp to hold the valve open, typically 5 to 10 microamps. Below 1 microamp, remove the sensor and check for a cracked or wet ceramic insulator or a bent, burned, or coated rod.
- End at the pinpoint: restore gas supply, calibrate the Gas valve, correct the wiring, or replace the Flame sensor (same manufacturer, model, and length) as the tests condemn. Technician work. → Shop the flame sensor at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Flame sensor.
Shop the Flame sensor at Amazon
Also tied to this fault: Gas valve - Shop at Amazon
Parts that commonly fix it
- Flame sensor$10–$60Shop at Amazon
- Gas valve$100–$355Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.
Related Slant/Fin Boiler Prodigy 21 (KC-50/KC-100) problems
- 3 flashes
- 4 flashes
- 5 flashes
- 6 flashes
- 7 flashes
- Continuous flashing (diagnostic LED)
- Steady on
- 1 flash
See all Slant/Fin Prodigy 21 (KC-50/KC-100) codes & guides →