Slant/Fin Boiler Prodigy 21 (KC-50/KC-100) 1 flash
What it should look like on your machine
then it repeats
1 flash - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
One flash of the Prodigy 21 diagnostic LED means the high limit has been open for one hour. The boiler overheated or the limit circuit opened and stayed open. The manual's causes are a defective high limit, a circulator not running, and zone valves not opening.
Likely causes
- High limit open for one hour
- Defective high limit
- Circulator not running
- Zone valves not opening
How to fix it — step by step
- Record the code before resetting anything: write down the display exactly as shown (1 flash) and whether the boiler was in a heating call, a hot-water call, or idle when it appeared.
- Safety: turn the thermostat down, switch off power to the boiler at the service switch and breaker, and close the manual gas shutoff if you smell gas or see scorching. Do not open the burner compartment if you smell gas; leave and call the gas supplier.
- Locate the part: the high limit control is on the boiler with its sensor in the boiler water; the circulator and zone valves are in the heating loop piping.
- Test: per the manual, raise the high limit setting substantially (water temperature may read higher than the gauge shows when there is no flow) and check continuity across the high limit contacts. Contacts that stay open condemn the limit. Then check for power to the circulator and to each zone valve on a call; power present with no movement condemns that device.
- End at the pinpoint: replace the High limit (same manufacturer and model, never set above 220 F), the Circulator, or the Zone valve, whichever the tests condemn. Technician work.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the High limit control.
Shop the High limit control at Amazon
Also tied to this fault: Circulator - Shop at Amazon; Zone valve - Shop at Amazon
Parts that commonly fix it
- High limit controlShop at Amazon
- CirculatorShop at Amazon
- Zone valveShop at Amazon
- Tools for this job, if you need them$15–$65
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.
Related Slant/Fin Boiler Prodigy 21 (KC-50/KC-100) problems
- 2 flashes
- 3 flashes
- 4 flashes
- 5 flashes
- 6 flashes
- 7 flashes
- Continuous flashing (diagnostic LED)
- Steady on
See all Slant/Fin Prodigy 21 (KC-50/KC-100) codes & guides →