Slant/Fin Boiler Victory VSPH series POWER + FLAME LEDs flashing

What this problem usually means

Flashing POWER and FLAME LEDs together is a control lockout: flame was sensed without a call for heat. The manual's remedy: remove the air box front panel, turn power off for at least 45 seconds, and check whether a pilot flame exists during the pre-purge period (the first 30 seconds). If a pilot flame exists then, replace the gas valve.

Likely causes

  1. Flame sensed without a call for heat
  2. Gas valve passing gas to the pilot when it should be closed
  3. Defective gas valve

How to fix it — step by step

  1. Record the code before resetting anything: write down the display exactly as shown (POWER + FLAME LEDs flashing) and whether the boiler was in a heating call, a hot-water call, or idle when it appeared.
  2. Safety: turn the thermostat down, switch off power to the boiler at the service switch and breaker, and close the manual gas shutoff if you smell gas or see scorching. Do not open the burner compartment if you smell gas; leave and call the gas supplier.
  3. Locate the part: the pilot and gas valve are behind the air box front panel; the gas valve is in the gas train feeding the pilot.
  4. Test: after the 45-second power-off and restore, watch the pre-purge period. A pilot flame present during pre-purge is the manual's proof the gas valve is passing gas and must be replaced; no flame with the pattern repeating points back to the control's flame sensing. → Shop the gas valve at Amazon
  5. End at the pinpoint: replace the Gas valve if a pilot flame exists during pre-purge; if no flame exists, the pinpoint is the flame sensing circuit of the Integrated boiler control. Technician work only.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $100–$355

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.

Related Slant/Fin Boiler Victory VSPH series problems