Slant/Fin Boiler Prodigy 21 (KC-50/KC-100) 7 flashes
What it should look like on your machine
then it repeats
7 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Seven flashes means an improper flame signal: a flame signal was detected when the gas valve should be closed. The manual's causes are a defective gas valve that does not shut off gas flow, and a shorted flame detector (coating on the rod, or material contacting the rod inside the ceramic or the combustion area).
Likely causes
- Flame signal detected with the gas valve supposed to be closed
- Defective gas valve not shutting off gas flow
- Flame detector shorted (coated rod or material contacting the rod)
How to fix it — step by step
- Record the code before resetting anything: write down the display exactly as shown (7 flashes) and whether the boiler was in a heating call, a hot-water call, or idle when it appeared.
- Safety: turn the thermostat down, switch off power to the boiler at the service switch and breaker, and close the manual gas shutoff if you smell gas or see scorching. Do not open the burner compartment if you smell gas; leave and call the gas supplier.
- Locate the part: the gas valve is in the gas train at the front of the boiler; the flame detector (sensor rod) is at the burner.
- Test: turn the gas valve knob to OFF and check whether gas flow actually stops. Flow that continues condemns the valve. If flow stops, remove the flame detector and check for coating on the rod or material contacting the rod inside the ceramic or combustion area.
- End at the pinpoint: replace the Gas valve if it passes gas when off (same manufacturer and model, then calibrate per the manual), or clean the rod and replace the Flame detector if it is shorted. Technician work only. → Shop the flame detector at Amazon → Shop the gas valve at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Gas valve.
Also tied to this fault: Flame detector - Shop at Amazon
Parts that commonly fix it
- Gas valve$100–$355Shop at Amazon
- Flame detectorShop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.
Related Slant/Fin Boiler Prodigy 21 (KC-50/KC-100) problems
- Continuous flashing (diagnostic LED)
- Steady on
- 1 flash
- 2 flashes
- 3 flashes
- 4 flashes
- 5 flashes
- 6 flashes
See all Slant/Fin Prodigy 21 (KC-50/KC-100) codes & guides →