Slant/Fin Boiler Victory VSPH series POWER + TSTAT/CIRC LEDs flashing
What this problem usually means
Flashing POWER and TSTAT/CIRC LEDs together is a control lockout indicating 48 VAC on the thermostat circuit, roughly double what that circuit should carry. The manual's remedy is to check and correct the thermostat or zone valve wiring. Wrong or doubled transformer feeds on the thermostat loop are what this pattern is reporting.
Likely causes
- 48 VAC on the thermostat circuit
- Thermostat wiring fault
- Zone valve wiring fault (wrong transformer feed)
How to fix it — step by step
- Record the code before resetting anything: write down the display exactly as shown (POWER + TSTAT/CIRC LEDs flashing) and whether the boiler was in a heating call, a hot-water call, or idle when it appeared.
- Safety: turn the thermostat down, switch off power to the boiler at the service switch and breaker, and close the manual gas shutoff if you smell gas or see scorching. Do not open the burner compartment if you smell gas; leave and call the gas supplier.
- Locate the part: the thermostat terminals on the integrated boiler control, and the zone valve wiring and any separate zone transformer feeding the thermostat loop.
- Test: measure the voltage on the thermostat circuit at the control. About 48 VAC confirms a doubled feed, usually a second transformer tied into the loop; normal 24 VAC with the pattern still flashing means recheck the wiring against the manual's diagram.
- End at the fix: correct the thermostat or zone valve wiring so the circuit carries only its proper control voltage, then reset the lockout by turning power off for at least 45 seconds and restoring it. Technician work.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Integrated boiler control.
Parts that commonly fix it
- Integrated boiler controlShop at Amazon
- Tools for this job, if you need them$15–$65
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.