York Heat pump Affinity, Echelon, Acclimate Heat Pump Series LED1 (red) on, LED2 (green) 3 flashes
What it should look like on your machine
then it repeats
3 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Three green flashes on LED2 with LED1 on is 'Liquid line sensor failure (short)' in Table 6 of the YorkGuard VI instructions, X/L output 2 flashes (soft). The liquid line sensor provides the coil/liquid temperature the demand defrost control compares against outdoor ambient to initiate and terminate defrost, and to run its freeze protection logic. A shorted sensor feeds the control a fixed, impossible temperature, so defrost timing cannot be trusted: the control flags the sensor fault instead of guessing. On the YHJF-family control in Johnson Controls' installation manual, the same liquid temperature input below its initiate point for 4.5 minutes is what starts a defrost, which shows how central this reading is.
Likely causes
- Liquid line sensor shorted internally
- Sensor leads shorted together or to ground
- Sensor connector contaminated or corroded
- Incorrect replacement sensor fitted
How to fix it — step by step
- Record the pattern (LED1 on, LED2 three flashes) before resetting; note whether defrost behavior has also been abnormal, which fits a bad liquid temperature input.
- Safety first: Turn the outdoor disconnect off and switch the breaker off, then verify the unit is dead with a meter before touching wiring; treat the run capacitor as charged and discharge it safely, because it can hold a charge after power is removed.
- Remove the control-box panel and locate the liquid line sensor clipped to the liquid line, then trace its leads to the defrost control, inspecting for chafe or pinch damage.
- Measure the sensor's resistance and the harness separately: near-zero at the sensor condemns the thermistor, while a correct sensor reading with a short measured at the board plug condemns the wiring. → Shop the thermistor at Amazon
- Replace a proven-bad defrost sensor (thermistor) in its original clip position on the liquid line, or repair the wiring, and verify a normal defrost initiation and termination.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Defrost sensor.
Shop the Defrost sensor at Amazon
Also tied to this fault: Thermistor - Shop at Amazon
Parts that commonly fix it
- Defrost sensor$25–$80Shop at Amazon
- Thermistor$25–$80Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.
Related York Heat pump Affinity, Echelon, Acclimate Heat Pump Series problems
- LED1 (red) on, LED2 (green) 4 flashes
- LED1 (red) on, LED2 (green) 5 flashes
- LED1 (red) on, LED2 (green) 6 flashes
- LED1 (red) on, LED2 (green) 7 flashes
- LED1 (red) on, LED2 (green) 8 flashes
- LED1 (red) on, LED2 (green) 9 flashes
- LED1 (red) on, LED2 (green) off
- 1 flash (LED1 red), LED2 (green) on
- 1 flash (LED1 red), LED2 off
- 2 flashes (LED1 red), LED2 (green) on
- 2 flashes (LED1 red), LED2 off
- 3 flashes (LED1 red), LED2 (green) on
See all York Affinity, Echelon, Acclimate Heat Pump Series codes & guides →