York Heat pump Affinity, Echelon, Acclimate Heat Pump Series LED1 (red) on, LED2 (green) 7 flashes
What it should look like on your machine
then it repeats
7 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Seven green flashes on LED2 with LED1 on is 'Discharge line sensor failure (short)' in Table 6 of the YorkGuard VI instructions, under Optional Discharge Line Sensor Faults, X/L output 2 flashes (soft). It applies only where the optional discharge line sensor is fitted. A shorted sensor reports a fixed out-of-range value, so the control can no longer use discharge temperature either to protect the compressor from overheating or to detect abnormal operation, and it raises this dedicated fault instead. As with the other sensor codes, the failure can be in the sensor element itself or anywhere in its wiring back to the demand defrost control.
Likely causes
- Discharge sensor shorted internally
- Sensor leads shorted or pinched against the cabinet or piping
- Moisture or corrosion in the sensor connector
- Wrong sensor fitted during a previous repair
How to fix it — step by step
- Record the pattern (LED1 on, LED2 seven flashes) before resetting, distinguishing it from the operational seven-flash code where LED2 stays off.
- Safety first: Turn the outdoor disconnect off and switch the breaker off, then verify the unit is dead with a meter before touching wiring; treat the run capacitor as charged and discharge it safely, because it can hold a charge after power is removed.
- Remove the control-box panel, locate the discharge sensor on the compressor discharge line and trace its leads to the defrost control, looking for pinch or chafe points.
- Measure the sensor's resistance disconnected from the board, then check the harness for shorts: near-zero at the sensor condemns the thermistor, while a good sensor with a short at the board plug condemns the wiring. → Shop the thermistor at Amazon
- Replace a proven-bad thermistor or repair the wiring, then run the unit and confirm the sensor code clears and discharge protection is back in service.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Thermistor.
Parts that commonly fix it
- Thermistor$25–$80Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.
Related York Heat pump Affinity, Echelon, Acclimate Heat Pump Series problems
- LED1 (red) on, LED2 (green) 8 flashes
- LED1 (red) on, LED2 (green) 9 flashes
- LED1 (red) on, LED2 (green) off
- 1 flash (LED1 red), LED2 (green) on
- 1 flash (LED1 red), LED2 off
- 2 flashes (LED1 red), LED2 (green) on
- 2 flashes (LED1 red), LED2 off
- 3 flashes (LED1 red), LED2 (green) on
- 3 flashes (LED1 red), LED2 off
- 4 flashes (LED1 red), LED2 off
- 5 flashes (LED1 red), LED2 off
- 6 flashes (LED1 red), LED2 off
See all York Affinity, Echelon, Acclimate Heat Pump Series codes & guides →