York Heat pump Affinity, Echelon, Acclimate Heat Pump Series LED1 (red) on, LED2 (green) 4 flashes
What it should look like on your machine
then it repeats
4 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Four green flashes on LED2 with LED1 on is 'Liquid line sensor failure (open)' in Table 6 of the YorkGuard VI instructions, X/L output 2 flashes (soft). The liquid line sensor is a required input: the demand defrost control uses its temperature, with outdoor ambient, to decide defrost initiation, termination and freeze protection. An open circuit, whether a failed sensor element, a broken lead or an unplugged connector, reads out of range and the control raises this fault rather than running defrost blind. The manual notes sensor faults like this commonly show up at installation or after a component is replaced or rewired, so recent service is a strong clue.
Likely causes
- Liquid line sensor failed open
- Sensor unplugged at the control after service
- Broken or corroded sensor lead
- Sensor clip lost so the sensor is not reading the line (reads out of expected range)
How to fix it — step by step
- Record the pattern (LED1 on, LED2 four flashes) before cycling power, and note any recent service on the outdoor unit.
- Safety first: Turn the outdoor disconnect off and switch the breaker off, then verify the unit is dead with a meter before touching wiring; treat the run capacitor as charged and discharge it safely, because it can hold a charge after power is removed.
- Remove the control-box panel, confirm the liquid line sensor is plugged into the defrost control and still clipped firmly to the liquid line, and inspect its leads end to end.
- Measure resistance at the sensor itself and then through the harness at the board: open at the sensor condemns the thermistor, open only through the harness condemns the wiring or connector, and a good reading everywhere suggests the sensor had simply been left unplugged. → Shop the thermistor at Amazon
- Replace a proven-bad defrost sensor or repair the connection, then run the unit and force a defrost with the TEST pins to confirm normal initiation and termination.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Defrost sensor.
Shop the Defrost sensor at Amazon
Also tied to this fault: Thermistor - Shop at Amazon
Parts that commonly fix it
- Defrost sensor$25–$80Shop at Amazon
- Thermistor$25–$80Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.
Related York Heat pump Affinity, Echelon, Acclimate Heat Pump Series problems
- LED1 (red) on, LED2 (green) 5 flashes
- LED1 (red) on, LED2 (green) 6 flashes
- LED1 (red) on, LED2 (green) 7 flashes
- LED1 (red) on, LED2 (green) 8 flashes
- LED1 (red) on, LED2 (green) 9 flashes
- LED1 (red) on, LED2 (green) off
- 1 flash (LED1 red), LED2 (green) on
- 1 flash (LED1 red), LED2 off
- 2 flashes (LED1 red), LED2 (green) on
- 2 flashes (LED1 red), LED2 off
- 3 flashes (LED1 red), LED2 (green) on
- 3 flashes (LED1 red), LED2 off
See all York Affinity, Echelon, Acclimate Heat Pump Series codes & guides →