York Heat pump Affinity, Echelon, Acclimate Heat Pump Series LED1 (red) on, LED2 (green) 8 flashes

What it should look like on your machine

then it repeats

8 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Eight green flashes on LED2 with LED1 on is 'Bonnet sensor failure (short)' in Table 6 of the YorkGuard VI instructions, under Optional Bonnet Sensor Faults, X/L output 2 flashes (soft). The bonnet sensor is an optional input used on fossil-fuel (dual-fuel) applications, where the control needs to know the indoor plenum temperature to manage the changeover between the heat pump and a furnace. A shorted bonnet sensor gives the control an impossible plenum temperature, so on a dual-fuel system this fault can disrupt auxiliary heat changeover even though the heat pump itself is mechanically sound. On a system with no bonnet sensor fitted, this code points at wiring or configuration instead.

Likely causes

  1. Bonnet sensor shorted internally
  2. Bonnet sensor wiring shorted
  3. Moisture or corrosion at the sensor connection
  4. Sensor circuit connected on a system not configured for it

How to fix it — step by step

  1. Record the pattern (LED1 on, LED2 eight flashes) and establish whether the system is actually a dual-fuel installation with a bonnet sensor fitted, because that decides whether to hunt a sensor or a wiring/configuration error.
  2. Safety first: Turn the outdoor disconnect off and switch the breaker off, then verify the unit is dead with a meter before touching wiring; treat the run capacitor as charged and discharge it safely, because it can hold a charge after power is removed.
  3. Trace the bonnet sensor circuit from the defrost control toward the indoor unit, inspecting the low-voltage cable and the sensor at the plenum for damage or moisture.
  4. Measure the sensor's resistance and the harness separately: near-zero at the sensor condemns the thermistor, while a correct sensor with a short measured at the control condemns the cable run. → Shop the thermistor at Amazon
  5. Replace a proven-bad thermistor or repair the wiring, then run both heat pump and auxiliary heat calls to confirm normal dual-fuel changeover with no returning code.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $25–$80

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.