York Heat pump Affinity, Echelon, Acclimate Heat Pump Series LED1 (red) on, LED2 (green) 5 flashes

What it should look like on your machine

then it repeats

5 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Five green flashes on LED2 with LED1 on is 'High discharge line temperature' in Table 6 of the YorkGuard VI instructions, under Optional Discharge Line Sensor Faults, with an X/L output of 2 flashes (soft) or 3 (hard). This code only exists on units fitted with the optional discharge line sensor. It reports the compressor discharge temperature has gone above the control's limit, which happens when the compressor runs with low suction pressure, low charge or excessive head pressure and overheats. Because discharge temperature is the most direct measure of compressor distress, this code should be treated as a stop-and-diagnose warning, not cleared and forgotten.

Likely causes

  1. Low refrigerant charge overheating the compressor
  2. Refrigerant restriction starving suction
  3. High head pressure from airflow failure or overcharge
  4. Discharge sensor reading falsely high

How to fix it — step by step

  1. Record the pattern (LED1 on, LED2 five flashes) and leave the unit off until the cause is checked; an overheated compressor is damaged further by repeated starts.
  2. Safety first: Turn the outdoor disconnect off and switch the breaker off, then verify the unit is dead with a meter before touching wiring; treat the run capacitor as charged and discharge it safely, because it can hold a charge after power is removed.
  3. Remove the control-box panel and locate the discharge line sensor on the compressor discharge line and its connection to the defrost control; inspect mounting and wiring.
  4. A technician should measure actual discharge line temperature and compare it with pressures and charge: genuinely high temperature with low suction points to charge or restriction, while a normal measured temperature condemns the sensor or its circuit.
  5. Correct the charge or restriction only through an EPA-certified technician, or replace a proven-bad thermistor, then monitor a full run to confirm discharge temperature stays in range.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $25–$80

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.

Related York Heat pump Affinity, Echelon, Acclimate Heat Pump Series problems

See all York Affinity, Echelon, Acclimate Heat Pump Series codes & guides →