York Heat pump Affinity, Echelon, Acclimate Heat Pump Series 2 flashes (LED1 red), LED2 off

What it should look like on your machine

then it repeats

2 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Table 5 of the YorkGuard VI instructions lists two red flashes on LED1 with LED2 off as 'High-pressure switch lockout (last mode of operation was heat pump)', with the X/L thermostat output flashing 2 for a soft lockout or 3 for a hard lockout. The control locks out after repeated switch openings inside its six-hour accumulated run-time window; a soft lockout resets by interrupting the thermostat call after the fault is corrected, while a hard lockout needs system power cycled. The 'last mode was heat pump' detail matters: the pressure trip happened in normal heating or cooling, not during a defrost cycle, which separates this code from the three-flash defrost version.

Likely causes

  1. Refrigerant overcharge raising discharge pressure
  2. Outdoor fan failure or dirty coil in cooling
  3. Indoor airflow failure in heating (filter, blower, closed registers)
  4. Refrigerant restriction
  5. Pressure switch failing and tripping early

How to fix it — step by step

  1. Record the two-flash code and whether the thermostat X/L signal shows 2 (soft) or 3 (hard) flashes, because the reset method differs, per the manual's X/L categories table.
  2. Safety first: Turn the outdoor disconnect off and switch the breaker off, then verify the unit is dead with a meter before touching wiring; treat the run capacitor as charged and discharge it safely, because it can hold a charge after power is removed.
  3. Clean the outdoor coil, replace a clogged indoor filter, and remove the control-box panel to inspect the defrost control, contactor and pressure switch wiring.
  4. A technician should measure discharge and suction pressures against outdoor temperature and check charge; high pressure with good airflow points to overcharge or restriction, while normal pressure at trip condemns the switch. Also verify the outdoor fan motor current and capacitor on PSC models.
  5. Fix the proven cause first, then reset as the manual directs: interrupt the thermostat call for a soft lockout, or cycle system power for a hard lockout. Any refrigerant-side repair, charge adjustment or sealed-system work is EPA-certified-technician work only; do not open the refrigerant circuit yourself.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $5–$35

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.