York Heat pump Affinity, Echelon, Acclimate Heat Pump Series LED1 (red) on, LED2 (green) off
What it should look like on your machine
then it repeats
4 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Table 5 (Operational Fault Codes) of Johnson Controls document 501062-UAI-A-0909, for the YorkGuard VI demand defrost control used on Affinity, Echelon and Acclimate heat pumps, lists LED1 red on with LED2 green off as 'Control Failure that still allows fault code output', with an X/L output of 4 flashes if possible. The control displays operational faults by flashing LED1 only, so a steady red LED1 is not a flash count at all: the board itself has failed internally but can still signal. Because the same board runs defrost, the contactor outputs and the pressure-switch protection, a failed control means none of those protections can be trusted until it is replaced.
Likely causes
- Internal failure of the demand defrost control board
- Control damaged by a voltage surge or moisture
- Shorted output load damaging the control
How to fix it — step by step
- Record the steady LED1 pattern and confirm it is not a flash code; photograph the board's wiring before changing anything.
- Safety first: Turn the outdoor disconnect off and switch the breaker off, then verify the unit is dead with a meter before touching wiring; treat the run capacitor as charged and discharge it safely, because it can hold a charge after power is removed.
- Remove the outdoor unit's control-box panel to reach the demand defrost control (board model 340512/031-09178-000A in the manual) and inspect it for water damage, burned traces or loose plugs.
- Verify the board has a proper 24VAC supply between R and C: correct supply voltage with a steady fault LED and no outputs condemns the control itself, while missing or low voltage is a power problem to fix first (see the low-voltage codes).
- Replace a proven-failed defrost control board, transfer the defrost curve jumper and wiring exactly, clear fault memory with the LAST ERROR button as the manual directs, and run a full heating and defrost check.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Defrost control board.
Shop the Defrost control board at Amazon
Also tied to this fault: Control board - Shop at Amazon
Parts that commonly fix it
- Defrost control boardShop at Amazon
- Control boardShop at Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.
Related York Heat pump Affinity, Echelon, Acclimate Heat Pump Series problems
- 1 flash (LED1 red), LED2 (green) on
- 1 flash (LED1 red), LED2 off
- 2 flashes (LED1 red), LED2 (green) on
- 2 flashes (LED1 red), LED2 off
- 3 flashes (LED1 red), LED2 (green) on
- 3 flashes (LED1 red), LED2 off
- 4 flashes (LED1 red), LED2 off
- 5 flashes (LED1 red), LED2 off
- 6 flashes (LED1 red), LED2 off
- 7 flashes (LED1 red), LED2 off
- 8 flashes (LED1 red), LED2 (green) on
- LED1 (red) on, LED2 (green) 1 flash
See all York Affinity, Echelon, Acclimate Heat Pump Series codes & guides →