York Heat pump Affinity, Echelon, Acclimate Heat Pump Series 1 flash (LED1 red), LED2 (green) on

What it should look like on your machine

then it repeats

1 flash - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Table 7 (Wiring Related Fault Codes) of the YorkGuard VI instructions displays wiring faults by flashing LED1 red while LED2 green stays on; one red flash is 'Compressor Contactor Miswire', with an X/L output of 3 flashes (hard). The control can tell that the compressor contactor circuit is wired in a way that does not match the compressor outputs it is driving, for example a load landed on the wrong M terminal, which the manual separately warns against: no loads may be attached to the M1 terminal on two-stage systems, and none to M1 or M2 on single-stage systems, or incorrect system behavior results. This is an installation or control-replacement error, not a worn-out part.

Likely causes

  1. Contactor wired to the wrong compressor output terminal (M, M1 or M2)
  2. Load incorrectly landed on the M1 terminal
  3. Wiring changed during a control or contactor replacement
  4. Contactor coil circuit miswired

How to fix it — step by step

  1. Record the pattern (LED1 one flash, LED2 on) and do not run the unit until the wiring is verified, because a miswired contactor can run the wrong stage or backfeed outputs.
  2. Safety first: Turn the outdoor disconnect off and switch the breaker off, then verify the unit is dead with a meter before touching wiring; treat the run capacitor as charged and discharge it safely, because it can hold a charge after power is removed.
  3. Remove the control-box panel and compare every conductor on the defrost control's M, M1 and M2 terminals and the contactor coil circuit against the unit wiring diagram, terminal by terminal.
  4. Confirm no load is connected to M1 (or M2 on single-stage) as the manual warns, and that the contactor coil is driven from the correct output; move any landed wire to its diagram terminal rather than swapping parts.
  5. Restore power, cycle the operational mode display with the TEST pins as the manual describes to confirm the control sees the correct configuration, and run a full call to verify normal staging.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $10–$35

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.

Related York Heat pump Affinity, Echelon, Acclimate Heat Pump Series problems

See all York Affinity, Echelon, Acclimate Heat Pump Series codes & guides →