York Heat pump Affinity, Echelon, Acclimate Heat Pump Series LED1 (red) on, LED2 (green) 1 flash

What it should look like on your machine

then it repeats

1 flash - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Table 6 (Sensor or Switch Fault Codes) of the YorkGuard VI instructions displays sensor faults by energizing LED1 red constantly and flashing LED2 green; one green flash is 'Outdoor ambient sensor failure (short)', with an X/L output of 2 flashes (soft). The outdoor ambient sensor is one of the two temperature inputs the demand defrost control uses to decide when a defrost is needed, comparing ambient against liquid line temperature. A shorted sensor reports an impossible temperature, so the control flags it rather than defrosting on bad data. The manual notes these sensor faults can occur during operation or at installation while the heat pump is being configured.

Likely causes

  1. Ambient sensor shorted internally
  2. Sensor wiring shorted or pinched
  3. Water or corrosion shorting the sensor connector
  4. Sensor replaced with an incorrect part

How to fix it — step by step

  1. Record the pattern carefully: LED1 steady red with LED2 flashing once is a sensor code, not the operational one-flash code where LED2 stays off.
  2. Safety first: Turn the outdoor disconnect off and switch the breaker off, then verify the unit is dead with a meter before touching wiring; treat the run capacitor as charged and discharge it safely, because it can hold a charge after power is removed.
  3. Remove the control-box panel, find the outdoor ambient sensor (mounted where it senses outdoor air, with leads to the defrost control) and inspect its wiring run for pinch points and corrosion.
  4. Disconnect the sensor and measure its resistance, then check the harness for continuity to ground or between conductors: near-zero resistance at the sensor condemns the sensor (thermistor), while a good sensor with a short in the harness condemns the wiring. → Shop the thermistor at Amazon
  5. Replace a proven-bad thermistor or repair the wiring, restore power, and confirm the control returns to its normal status display with no sensor code.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $25–$80

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.

Related York Heat pump Affinity, Echelon, Acclimate Heat Pump Series problems

See all York Affinity, Echelon, Acclimate Heat Pump Series codes & guides →