York Heat pump Affinity, Echelon, Acclimate Heat Pump Series 7 flashes (LED1 red), LED2 off

What it should look like on your machine

then it repeats

7 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Seven red flashes on LED1 with LED2 off is the last row of Table 5 in the YorkGuard VI instructions: 'Pipe Freeze Protection Timer expiration', with X/L off. This is an operational protection entry rather than a pressure or voltage trip: the control's pipe freeze protection timing ran to expiration and the control flagged it instead of continuing normal operation. Because the chart gives this condition its own code at the end of the operational table, it should be read as the control reporting that its freeze-protection logic, which depends on the liquid line and ambient temperature inputs, could not complete normally, and the sensor inputs that feed that logic are the first things to verify.

Likely causes

  1. Liquid line or ambient sensor reading incorrectly, corrupting the protection timing
  2. Defrost control fault in the protection logic
  3. Sensor wiring damaged or poorly connected
  4. Control board failing

How to fix it — step by step

  1. Record the seven-flash code and the outdoor temperature and recent operating history before cycling power, because the code is stored and can be recalled with the LAST ERROR button.
  2. Safety first: Turn the outdoor disconnect off and switch the breaker off, then verify the unit is dead with a meter before touching wiring; treat the run capacitor as charged and discharge it safely, because it can hold a charge after power is removed.
  3. Remove the control-box panel to reach the demand defrost control and check the liquid line sensor and outdoor ambient sensor mountings and connectors, since freeze protection depends on those inputs.
  4. Measure both sensors' resistance against their actual temperatures and compare with the control's expectations; a sensor far off its real temperature explains a protection timer fault, while correct sensors with a repeating code condemn the control.
  5. Replace a proven-bad thermistor sensor or the defrost control board, clear the stored fault memory as the manual directs, and run a heating cycle to confirm the code does not return.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $25–$80

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.

Related York Heat pump Affinity, Echelon, Acclimate Heat Pump Series problems

See all York Affinity, Echelon, Acclimate Heat Pump Series codes & guides →