York Heat pump Affinity, Echelon, Acclimate Heat Pump Series 5 flashes (LED1 red), LED2 off
What it should look like on your machine
then it repeats
5 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Five red flashes on LED1 with LED2 off is 'Low Voltage (less than 19 VAC) preventing further relay outputs' in Table 5 of the YorkGuard VI instructions, and its X/L output is off. The manual's low voltage detection section explains the behavior: the control monitors the transformer secondary, and if voltage drops below approximately 19 VAC it will keep any already-energized relays energized but will not energize any additional relays until the voltage rises, specifically to prevent contactor chatter. So with this code the heat pump may finish a running cycle but will not start the next stage or cycle, which looks like a dead unit even though the board is protecting the contactors.
Likely causes
- Undersized or failing control transformer
- Loose or corroded 24V wiring connections
- Partial short in a low-voltage load dragging the secondary down
- Low line voltage feeding the transformer
How to fix it — step by step
- Record the five-flash code and whether the unit completes a running cycle but will not start a new one, which matches the manual's description of this threshold.
- Safety first: Turn the outdoor disconnect off and switch the breaker off, then verify the unit is dead with a meter before touching wiring; treat the run capacitor as charged and discharge it safely, because it can hold a charge after power is removed.
- Locate the 24V supply at the demand defrost control (R and C terminals) in the outdoor control box and inspect the low-voltage wiring for damage, loose screws or corrosion.
- Measure the secondary at the control with a meter: the manual's threshold is the test, so sustained readings below about 19 VAC confirm the code, and the reading should be checked both idle and when a contactor tries to pull in, because a weak transformer or partial short only sags under load.
- Repair the wiring, remove the shorted load or replace a proven-weak transformer or control, then confirm the secondary holds above 19 VAC when outputs energize.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Control board.
Parts that commonly fix it
- Control boardShop at Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.
Related York Heat pump Affinity, Echelon, Acclimate Heat Pump Series problems
- 6 flashes (LED1 red), LED2 off
- 7 flashes (LED1 red), LED2 off
- 8 flashes (LED1 red), LED2 (green) on
- LED1 (red) on, LED2 (green) 1 flash
- LED1 (red) on, LED2 (green) 2 flashes
- LED1 (red) on, LED2 (green) 3 flashes
- LED1 (red) on, LED2 (green) 4 flashes
- LED1 (red) on, LED2 (green) 5 flashes
- LED1 (red) on, LED2 (green) 6 flashes
- LED1 (red) on, LED2 (green) 7 flashes
- LED1 (red) on, LED2 (green) 8 flashes
- LED1 (red) on, LED2 (green) 9 flashes
See all York Affinity, Echelon, Acclimate Heat Pump Series codes & guides →