York Heat pump Affinity, Echelon, Acclimate Heat Pump Series 4 flashes (LED1 red), LED2 off
What it should look like on your machine
then it repeats
4 flashes - then the pattern repeats. Count along with your machine and compare.
What this problem usually means
Table 5 of the YorkGuard VI instructions lists four red flashes on LED1 with LED2 off as 'Low-pressure switch lockout', with an X/L output of 2 flashes for a soft lockout or 3 for a hard lockout. Unlike the high-pressure codes, the chart has no separate first-trip low-pressure flash on this control: by the time it displays, repeated low-pressure (loss-of-charge) switch openings have already locked the compressor out. Low suction pressure most often means low refrigerant charge, a restriction, or airflow so poor the coil starves, and running a compressor in that state risks overheating and poor oil return, which is why the control stops it.
Likely causes
- Refrigerant leak or undercharge (loss of charge switch opening)
- Indoor or outdoor airflow severely restricted
- Metering device restricted or stuck
- Outdoor fan or indoor blower failure collapsing pressures
- Low pressure switch or wiring fault
How to fix it — step by step
- Record the four-flash code and do not keep resetting it; a loss-of-charge lockout means the compressor has already been protected several times.
- Safety first: Turn the outdoor disconnect off and switch the breaker off, then verify the unit is dead with a meter before touching wiring; treat the run capacitor as charged and discharge it safely, because it can hold a charge after power is removed.
- Replace a clogged filter, clear both coils, and remove the control-box panel to inspect the defrost control and the pressure switch circuit wiring.
- A technician should connect gauges and compare suction pressure with expected values for the conditions, then leak-check if pressure is low; low pressure with correct airflow indicates charge or restriction, while normal standing and running pressures with a lockout history condemn the switch or its circuit.
- Repair the leak or restriction and recharge only through an EPA-certified technician; replace a proven-bad switch. Reset by interrupting the thermostat call (soft) or cycling power (hard), per the manual.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Air filter.
Parts that commonly fix it
- Air filter$5–$30Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.
Related York Heat pump Affinity, Echelon, Acclimate Heat Pump Series problems
- 5 flashes (LED1 red), LED2 off
- 6 flashes (LED1 red), LED2 off
- 7 flashes (LED1 red), LED2 off
- 8 flashes (LED1 red), LED2 (green) on
- LED1 (red) on, LED2 (green) 1 flash
- LED1 (red) on, LED2 (green) 2 flashes
- LED1 (red) on, LED2 (green) 3 flashes
- LED1 (red) on, LED2 (green) 4 flashes
- LED1 (red) on, LED2 (green) 5 flashes
- LED1 (red) on, LED2 (green) 6 flashes
- LED1 (red) on, LED2 (green) 7 flashes
- LED1 (red) on, LED2 (green) 8 flashes
See all York Affinity, Echelon, Acclimate Heat Pump Series codes & guides →