Rheem Heat pump Error Codes

Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 15 codes covered.

Not sure of the code? Tap along with it

If your Rheem Heat pump blinks or beeps a pattern instead of showing a code, tap the button in time with each blink or beep. A pause longer than a second and a half starts a new group - we will match the rhythm to a code.

Your taps: -

Finding your model number: it is on the outdoor unit's rating plate.

Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.

RP14 demand defrost control (two-LED codes)

Two diagnostic LEDs on the Enhanced Feature Demand Defrost Control inside the outdoor control box combine into the fault patterns.

CodeWhat it meansCheck first
LED 1 FLASH / LED 2 OFFRead on the two diagnostic LEDs of the Enhanced Feature Demand Defrost Control inside the outdoor unit…Dirty or blocked outdoor coil restricting heat rejection in cooling›
LED 1 FLASH / LED 2 ONRead on the two diagnostic LEDs of the Enhanced Feature Demand Defrost Control inside the outdoor unit…Dirty or blocked outdoor coil in cooling›
LED 1 OFF / LED 2 FLASHRead on the two diagnostic LEDs of the Enhanced Feature Demand Defrost Control inside the outdoor unit…Low refrigerant charge from a leak›
LED 1 OFF / LED 2 OFFRead on the two diagnostic LEDs of the Enhanced Feature Demand Defrost Control inside the outdoor unit…No 24 VAC control power reaching the defrost board from the indoor unit or transformer›
LED 1 OFF / LED 2 ONRead on the two diagnostic LEDs of the Enhanced Feature Demand Defrost Control inside the outdoor unit…Ambient sensor failed open or shorted›
LED 1 ON / LED 2 FLASHRead on the two diagnostic LEDs of the Enhanced Feature Demand Defrost Control inside the outdoor unit…Low refrigerant charge from a leak›
LED 1 ON / LED 2 ONRead on the two diagnostic LEDs of the Enhanced Feature Demand Defrost Control inside the outdoor unit…Coil sensor failed open or shorted›

RP20 variable speed (7-segment + EcoNet)

Codes show on the VSODC dual 7-segment display in the outdoor unit and as fault codes at the EcoNet thermostat; an L prefix means the fault has locked the unit out.

CodeWhat it meansCheck first
21 / L21Read as 21, or L21 once locked out, on the dual 7-segment LED of the Variable Speed Outdoor Control in the…Low refrigerant charge from a leak›
29 / L29Read as 29, or L29 once locked out, on the dual 7-segment LED of the Variable Speed Outdoor Control in the…Dirty outdoor coil restricting heat rejection›
4 / L04Read as 4 or L04 on the dual 7-segment LED of the Variable Speed Outdoor Control in the outdoor unit (the…Weak or failed run capacitor›
48Read as 48 on the dual 7-segment LED of the Variable Speed Outdoor Control in the outdoor unit, and as EcoNet…Contactor not pulling in - no 24 VAC at its coil or a failed coil›
49Read as 49 on the dual 7-segment LED of the Variable Speed Outdoor Control in the outdoor unit, and as EcoNet…Contactor contacts welded shut from repeated high-current starts›
84Read as 84 on the dual 7-segment LED of the Variable Speed Outdoor Control in the outdoor unit, and as EcoNet…Thermistor disconnected at its plug›
9 / L9Read as 9, or L9 once locked out, on the dual 7-segment LED of the Variable Speed Outdoor Control in the…Loose connections in the line-voltage wiring›
d1Read as d1 on the dual 7-segment LED of the Variable Speed Outdoor Control in the outdoor unit, and as EcoNet…Corrupt firmware in the Variable Speed Outdoor Control (VSODC)›

Common questions

What does LED 1 off and LED 2 flashing mean on a Rheem RP14?
A low pressure lockout. On the demand defrost control, LED 1 off with LED 2 flashing is the chart's low pressure lockout; the manual resets it by shorting the test pins.

What does the L mean in a Rheem code like L21?
Lockout. Variable-speed Rheem units show the plain number while the fault is active and add the L prefix (21 becomes L21) once the control has locked the unit out after repeated trips.

Looking for a part?

Once you know the part you need, browse Rheem Heat pump replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.