Rheem RP20 variable-speed heat pumps with Variable Speed Outdoor Control (VSODC) and EcoNet Error Codes

Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 8 codes covered.

Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.

CodeWhat it meansCheck first
21 / L21Read as 21, or L21 once locked out, on the dual 7-segment LED of the Variable Speed Outdoor Control in the…Low refrigerant charge from a leak›
29 / L29Read as 29, or L29 once locked out, on the dual 7-segment LED of the Variable Speed Outdoor Control in the…Dirty outdoor coil restricting heat rejection›
4 / L04Read as 4 or L04 on the dual 7-segment LED of the Variable Speed Outdoor Control in the outdoor unit (the…Weak or failed run capacitor›
48Read as 48 on the dual 7-segment LED of the Variable Speed Outdoor Control in the outdoor unit, and as EcoNet…Contactor not pulling in - no 24 VAC at its coil or a failed coil›
49Read as 49 on the dual 7-segment LED of the Variable Speed Outdoor Control in the outdoor unit, and as EcoNet…Contactor contacts welded shut from repeated high-current starts›
84Read as 84 on the dual 7-segment LED of the Variable Speed Outdoor Control in the outdoor unit, and as EcoNet…Thermistor disconnected at its plug›
9 / L9Read as 9, or L9 once locked out, on the dual 7-segment LED of the Variable Speed Outdoor Control in the…Loose connections in the line-voltage wiring›
d1Read as d1 on the dual 7-segment LED of the Variable Speed Outdoor Control in the outdoor unit, and as EcoNet…Corrupt firmware in the Variable Speed Outdoor Control (VSODC)›

All Rheem heat pump models & codes →