Rheem Heat pump RP14 (14 SEER) heat pump outdoor units - Enhanced Feature Demand Defrost Control LED 1 FLASH / LED 2 OFF Error Code

What it should look like on your machine

then it repeats

1 flash - then the pattern repeats. Count along with your machine and compare.

What the LED 1 FLASH / LED 2 OFF code means

Read on the two diagnostic LEDs of the Enhanced Feature Demand Defrost Control inside the outdoor unit control box. LED 1 flashing with LED 2 off is the chart's 'High Pressure Lockout (short test pins to reset)'. The manual states the high pressure control opens at approximately 610 psig and closes again at approximately 420 psig, stopping the compressor and fan each time; if the control opens three times within a particular call for heating or cooling, the defrost control locks out compressor and outdoor fan operation entirely. This is a protective lockout - the system saw discharge pressure high enough, repeatedly, to risk compressor damage.

Likely causes

  1. Dirty or blocked outdoor coil restricting heat rejection in cooling
  2. Outdoor fan motor not running or running weakly
  3. Refrigerant overcharge
  4. Indoor airflow or reversing-valve problem driving head pressure up in heating

How to fix it — step by step

  1. Record the code first: note LED 1 flashing / LED 2 off and the operating mode before resetting - the lockout count is the clue.
  2. Safety: turn power off at the outdoor disconnect and the breaker, verify dead with a meter, and observe capacitor caution. Refrigerant-side work is EPA-certified tech only.
  3. Locate the parts: inspect the outdoor coil through the grille for dirt and debris, and the outdoor fan and its run capacitor in the control box and fan deck.
  4. Test: clean the coil and confirm the fan runs at full speed on a call; a technician then measures discharge pressure against the switch points (opens about 610 psig, resets about 420 psig) and verifies charge - normal pressures with repeat trips condemn the switch or board, high pressures pinpoint airflow or charge.
  5. End at the fix: correct the airflow, fan or charge cause, then exit lockout by removing 24 volts to the defrost control or shorting the two test pins together, per the manual, and monitor a full cycle.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the LED 1 FLASH / LED 2 OFF code

Parts run $5–$35

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.