What the LED 1 OFF / LED 2 OFF code means
Read on the two diagnostic LEDs of the Enhanced Feature Demand Defrost Control inside the outdoor unit control box. Both LEDs dark is the chart's 'No Power' status: the defrost control board is not receiving the control power it needs to operate, so it cannot run the compressor or outdoor fan, monitor the coil and ambient sensors, apply its high- and low-pressure protection, or time a defrost cycle. This is a board power-supply indication rather than a refrigerant or sensor fault, and it must be resolved before any other LED pattern on the board can be trusted.
Likely causes
- No 24 VAC control power reaching the defrost board from the indoor unit or transformer
- Tripped breaker or open outdoor disconnect cutting power to the system
- Blown low-voltage fuse or a loose or broken R/C control wire at the board
- Failed defrost control board
How to fix it — step by step
- Record the code first: note both LEDs are dark and whether the thermostat is calling, before cycling any power.
- Safety: turn power off at the outdoor disconnect and the breaker, verify the unit is dead with a meter, and treat the run capacitor as charged until it is discharged.
- Locate the part: remove the outdoor unit control-box cover to reach the defrost control board and its R and C terminals.
- Test: restore power briefly and measure across R and C at the board; about 24 VAC means power is present and the board itself has failed, while 0 VAC means the loss is upstream in the fuse, transformer or control wiring - trace it until 24 VAC is restored.
- End at the fix: repair the upstream power fault or replace the defrost control board, then confirm both LEDs light in the normal flashing pattern on a call.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the Defrost control board.
Parts that commonly fix the LED 1 OFF / LED 2 OFF code
- Defrost control boardShop at Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.