Rheem Heat pump RP14 (14 SEER) heat pump outdoor units - Enhanced Feature Demand Defrost Control LED 1 ON / LED 2 FLASH Error Code

What it should look like on your machine

then it repeats

2 flashes - then the pattern repeats. Count along with your machine and compare.

What the LED 1 ON / LED 2 FLASH code means

Read on the two diagnostic LEDs of the Enhanced Feature Demand Defrost Control inside the outdoor unit control box. LED 1 on steady with LED 2 flashing is the chart's 'Low Pressure Control Open'. Unlike the low-pressure lockout pattern, this says the low pressure switch is open right now: suction pressure has fallen to roughly the switch's opening point of approximately 15 psig, and the compressor and fan have stopped. Because the switch is automatic-reset, the unit will try to restart when pressure rises to approximately 40 psig. Repeated openings - three in one cooling call or three within 120 minutes in heating - escalate into a lockout.

Likely causes

  1. Low refrigerant charge from a leak
  2. Restriction in the refrigerant circuit or a metering device not feeding correctly
  3. Dirty indoor air filter or weak indoor airflow in cooling
  4. Frosted outdoor coil or very cold outdoor temperature in heating

How to fix it — step by step

  1. Record the code first: note LED 1 on / LED 2 flashing and whether the unit restarts on its own as pressure recovers, before cycling power.
  2. Safety: turn power off at the outdoor disconnect and the breaker, verify dead with a meter, and observe capacitor caution. Refrigerant-side work is EPA-certified tech only.
  3. Locate the parts: check the indoor air filter first, then the defrost board in the outdoor control box and the low pressure switch on the suction line.
  4. Test: a technician connects gauges and watches suction pressure through a call - pressure sagging to about 15 psig confirms a real low-pressure event from charge, restriction or airflow, while normal pressure with the switch open condemns the switch or its wiring.
  5. End at the fix: correct the charge, restriction or airflow cause (or replace a proven-bad pressure switch), restore power, and confirm the switch closes near 40 psig and the unit completes a full call without reopening.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the LED 1 ON / LED 2 FLASH code

Parts run $5–$30

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.

Related Rheem Heat pump RP14 (14 SEER) heat pump outdoor units - Enhanced Feature Demand Defrost Control error codes

See all Rheem RP14 (14 SEER) heat pump outdoor units - Enhanced Feature Demand Defrost Control codes & guides →