Rheem Heat pump RP14 (14 SEER) heat pump outdoor units - Enhanced Feature Demand Defrost Control LED 1 ON / LED 2 FLASH Error Code
What it should look like on your machine
then it repeats
2 flashes - then the pattern repeats. Count along with your machine and compare.
What the LED 1 ON / LED 2 FLASH code means
Read on the two diagnostic LEDs of the Enhanced Feature Demand Defrost Control inside the outdoor unit control box. LED 1 on steady with LED 2 flashing is the chart's 'Low Pressure Control Open'. Unlike the low-pressure lockout pattern, this says the low pressure switch is open right now: suction pressure has fallen to roughly the switch's opening point of approximately 15 psig, and the compressor and fan have stopped. Because the switch is automatic-reset, the unit will try to restart when pressure rises to approximately 40 psig. Repeated openings - three in one cooling call or three within 120 minutes in heating - escalate into a lockout.
Likely causes
- Low refrigerant charge from a leak
- Restriction in the refrigerant circuit or a metering device not feeding correctly
- Dirty indoor air filter or weak indoor airflow in cooling
- Frosted outdoor coil or very cold outdoor temperature in heating
How to fix it — step by step
- Record the code first: note LED 1 on / LED 2 flashing and whether the unit restarts on its own as pressure recovers, before cycling power.
- Safety: turn power off at the outdoor disconnect and the breaker, verify dead with a meter, and observe capacitor caution. Refrigerant-side work is EPA-certified tech only.
- Locate the parts: check the indoor air filter first, then the defrost board in the outdoor control box and the low pressure switch on the suction line.
- Test: a technician connects gauges and watches suction pressure through a call - pressure sagging to about 15 psig confirms a real low-pressure event from charge, restriction or airflow, while normal pressure with the switch open condemns the switch or its wiring.
- End at the fix: correct the charge, restriction or airflow cause (or replace a proven-bad pressure switch), restore power, and confirm the switch closes near 40 psig and the unit completes a full call without reopening.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Air filter.
Also tied to this fault: Defrost control board - Shop at Amazon
Parts that commonly fix the LED 1 ON / LED 2 FLASH code
- Air filter$5–$30Shop at Amazon
- Defrost control boardShop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.