Rheem RP14 (14 SEER) heat pump outdoor units - Enhanced Feature Demand Defrost Control Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 7 codes covered.
Not sure of the code? Tap along with it
If your Rheem Heat pump blinks or beeps a pattern instead of showing a code, tap the button in time with each blink or beep. A pause longer than a second and a half starts a new group - we will match the rhythm to a code.
Your taps: -
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
| Code | What it means | Check first | |
|---|---|---|---|
| LED 1 FLASH / LED 2 OFF | Read on the two diagnostic LEDs of the Enhanced Feature Demand Defrost Control inside the outdoor unit… | Dirty or blocked outdoor coil restricting heat rejection in cooling | › |
| LED 1 FLASH / LED 2 ON | Read on the two diagnostic LEDs of the Enhanced Feature Demand Defrost Control inside the outdoor unit… | Dirty or blocked outdoor coil in cooling | › |
| LED 1 OFF / LED 2 FLASH | Read on the two diagnostic LEDs of the Enhanced Feature Demand Defrost Control inside the outdoor unit… | Low refrigerant charge from a leak | › |
| LED 1 OFF / LED 2 OFF | Read on the two diagnostic LEDs of the Enhanced Feature Demand Defrost Control inside the outdoor unit… | No 24 VAC control power reaching the defrost board from the indoor unit or transformer | › |
| LED 1 OFF / LED 2 ON | Read on the two diagnostic LEDs of the Enhanced Feature Demand Defrost Control inside the outdoor unit… | Ambient sensor failed open or shorted | › |
| LED 1 ON / LED 2 FLASH | Read on the two diagnostic LEDs of the Enhanced Feature Demand Defrost Control inside the outdoor unit… | Low refrigerant charge from a leak | › |
| LED 1 ON / LED 2 ON | Read on the two diagnostic LEDs of the Enhanced Feature Demand Defrost Control inside the outdoor unit… | Coil sensor failed open or shorted | › |
All Rheem heat pump models & codes →
Once you know the part you need, browse Rheem RP14 (14 SEER) heat pump outdoor units - Enhanced Feature Demand Defrost Control replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.