Rheem Heat pump RP20 variable-speed heat pumps with Variable Speed Outdoor Control (VSODC) and EcoNet 4 / L04 Error Code
What the 4 / L04 code means
Read as 4 or L04 on the dual 7-segment LED of the Variable Speed Outdoor Control in the outdoor unit (the fault page also shows it as 04 or L04), and as EcoNet fault T960_O or A960_O at the EcoNet thermostat. Rheem's fault page calls this 'Compressor Locked Rotor' and states it means the compressor is pulling excessive current at start-up. It gives three root directions: off-cycle refrigerant migration leaving the compressor full of refrigerant, a weak capacitor, or a tight or seized compressor. Distinguishing a start-assist or migration problem from a mechanically seized compressor is the whole diagnostic job on this code.
Likely causes
- Weak or failed run capacitor
- Liquid refrigerant migrated into the compressor during a long off cycle
- Tight or seized compressor
- Low supply voltage aggravating a hard start
How to fix it — step by step
- Record the code first: note 4 versus L04 (EcoNet T960_O/A960_O) and how long the unit sat off before the failed start.
- Safety: turn power off at the outdoor disconnect and the breaker, verify dead with a meter, and discharge and treat the run capacitor as charged until proven otherwise.
- Locate the parts: the run capacitor and contactor are in the outdoor control box; the compressor is in the base of the unit, reached after removing the coil guard panels.
- Test: measure the capacitor and compare microfarads with its rating - a weak reading condemns it. Per Rheem's page, warm the top of the compressor shell to chase liquid refrigerant out and retry; a compressor that still draws locked-rotor current with a good capacitor and correct voltage is seized.
- End at the fix: replace a weak capacitor or correct the migration cause and confirm clean starts; a confirmed seized compressor is EPA-tech compressor replacement - call a pro.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Run capacitor.
Parts that commonly fix the 4 / L04 code
- Run capacitor$5–$35Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number