Rheem Heat pump RP14 (14 SEER) heat pump outdoor units - Enhanced Feature Demand Defrost Control LED 1 OFF / LED 2 ON Error Code
What the LED 1 OFF / LED 2 ON code means
Read on the two diagnostic LEDs of the Enhanced Feature Demand Defrost Control inside the outdoor unit control box. LED 1 off with LED 2 on steady is the chart's 'Ambient Sensor Failure': the board has lost a valid reading from the outdoor ambient (air) temperature sensor. The demand-defrost control compares ambient temperature against outdoor coil temperature to decide when a defrost is actually needed, so a failed ambient sensor removes half of that calculation. The heat pump may keep running, but defrost timing will be wrong, wasting energy or allowing frost to build on the coil.
Likely causes
- Ambient sensor failed open or shorted
- Sensor unplugged, or its lead damaged or corroded at the board plug
- Sensor displaced from its position outside the control box where it senses outdoor air
- Failed defrost control board sensor input
How to fix it — step by step
- Record the code first: note LED 1 off and LED 2 on steady, and the outdoor temperature at the time, before cycling power.
- Safety: turn power off at the outdoor disconnect and the breaker, verify dead with a meter, and observe capacitor caution before handling wiring.
- Locate the part: the ambient sensor sits outside the control box so it can sense outdoor air, and its lead plugs into the defrost board; access is through the control-box cover.
- Test: unplug the sensor and measure its resistance against the manual's sensor table - about 10,000 ohms at 77 F (25 C) and about 32,650 ohms at 32 F (0 C). Open, shorted or badly off-table readings condemn the sensor; a correct reading shifts suspicion to the harness or board.
- End at the fix: replace the thermistor if it tests out of range, position it to sense outdoor air away from the coil discharge, restore power and confirm the LEDs return to the normal flashing pattern. → Shop the thermistor at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
Then the likely broken part is the Thermistor.
Also tied to this fault: Defrost control board - Shop at Amazon
Parts that commonly fix the LED 1 OFF / LED 2 ON code
- Thermistor$25–$80Shop at Amazon
- Defrost control boardShop at Amazon
- Tools for this job, if you need them$15–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.