Rheem Heat pump RP14 (14 SEER) heat pump outdoor units - Enhanced Feature Demand Defrost Control LED 1 ON / LED 2 ON Error Code

What the LED 1 ON / LED 2 ON code means

Read on the two diagnostic LEDs of the Enhanced Feature Demand Defrost Control inside the outdoor unit control box. Both LEDs on steady is the chart's 'Coil Sensor Failure': the board has detected that the outdoor coil temperature sensor is no longer giving a valid reading. That sensor tells the demand-defrost logic how cold the outdoor coil is, so without it the control cannot judge frost build-up correctly and normal demand defrost cannot be relied on. Left uncorrected, the outdoor coil can ice over in heating, airflow through the coil falls, and heating capacity drops sharply.

Likely causes

  1. Coil sensor failed open or shorted
  2. Sensor unplugged, or its lead damaged or corroded at the board plug
  3. Sensor displaced from its mounting point on the outdoor coil
  4. Failed defrost control board sensor input

How to fix it — step by step

  1. Record the code first: photograph LED 1 and LED 2 both on steady before cycling power, since the pattern clears clues once power is removed.
  2. Safety: turn power off at the outdoor disconnect and the breaker, verify dead with a meter, and observe capacitor caution before touching wiring.
  3. Locate the part: the coil sensor is clipped to the outdoor coil near the distribution tubes and plugs into the defrost board inside the control box; access is through the control-box cover and coil guard.
  4. Test: unplug the sensor and measure its resistance, then compare it with the manual's sensor table - about 10,000 ohms at 77 F (25 C), about 32,650 ohms at 32 F (0 C). A reading of open, shorted, or far off the table at a known temperature condemns the sensor; a correct reading points to the harness or the board.
  5. End at the fix: replace the defrost sensor if it tests out of range, refit it firmly to the coil, restore power and confirm the LEDs return to the normal flashing pattern and a test defrost initiates.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the LED 1 ON / LED 2 ON code

Parts run $25–$80

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.