Rheem Heat pump RP14 (14 SEER) heat pump outdoor units - Enhanced Feature Demand Defrost Control LED 1 OFF / LED 2 FLASH Error Code
What it should look like on your machine
then it repeats
2 flashes - then the pattern repeats. Count along with your machine and compare.
What the LED 1 OFF / LED 2 FLASH code means
Read on the two diagnostic LEDs of the Enhanced Feature Demand Defrost Control inside the outdoor unit control box. LED 1 off with LED 2 flashing is the chart's 'Low Pressure Lockout (short test pins to reset)'. The manual states the low pressure control is an automatic-reset switch that opens at approximately 15 psig and closes at approximately 40 psig; if it opens three times within one cooling call, or three times within 120 minutes in heating, the defrost control locks out the compressor and outdoor fan. A lockout below 5 F outdoors clears automatically when the temperature rises to 5 F, because very cold weather alone can open the switch.
Likely causes
- Low refrigerant charge from a leak
- Restriction in the refrigerant circuit or a metering device not feeding correctly
- Dirty indoor air filter or poor indoor airflow in cooling
- Very low outdoor temperature in heating (below about 5 F) rather than a true fault
How to fix it — step by step
- Record the code first: note LED 1 off / LED 2 flashing and the outdoor temperature before resetting anything - a lockout under 5 F may be weather, not a fault.
- Safety: turn power off at the outdoor disconnect and the breaker, verify dead with a meter, and observe capacitor caution. Refrigerant-side work is EPA-certified tech only.
- Locate the parts: find the defrost board and its test pins in the control box, and check the indoor air filter and coil for airflow restrictions you can correct without opening the refrigerant circuit.
- Test: a technician connects gauges to confirm suction pressure against the switch points (opens about 15 psig, closes about 40 psig) and checks charge and the metering device; repeated trips at normal pressures condemn the pressure switch or board, while genuinely low pressure pinpoints charge or restriction.
- End at the fix: correct the charge, restriction or airflow cause first, then exit lockout by removing 24 volts to the defrost control or shorting the two test pins together, per the manual, and watch a full call for repeat trips.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Air filter.
Also tied to this fault: Defrost control board - Shop at Amazon
Parts that commonly fix the LED 1 OFF / LED 2 FLASH code
- Air filter$5–$30Shop at Amazon
- Defrost control boardShop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.