Rheem Heat pump RP20 variable-speed heat pumps with Variable Speed Outdoor Control (VSODC) and EcoNet 29 / L29 Error Code

What the 29 / L29 code means

Read as 29, or L29 once locked out, on the dual 7-segment LED of the Variable Speed Outdoor Control in the outdoor unit, and as EcoNet fault T958_O or A958_O at the EcoNet thermostat. Rheem's fault page states this alarm means the high pressure switch has opened as a result of high refrigerant pressure. The system will lock out if the high pressure switch trips three times in a single cooling call. Because the switch is reacting to real discharge pressure, the page directs attention to refrigerant charge, the condition of the outdoor coil, and whether the outdoor fan motor is running as it should, rather than to the control board first.

Likely causes

  1. Dirty outdoor coil restricting heat rejection
  2. Outdoor fan motor not running or not running correctly
  3. Refrigerant overcharge
  4. Blocked airflow around the outdoor unit

How to fix it — step by step

  1. Record the code first: note 29 versus L29 and the EcoNet fault (T958_O/A958_O) before cycling power, since three trips in one cooling call is what locks the unit out.
  2. Safety: turn power off at the outdoor disconnect and the breaker, verify dead with a meter, and observe capacitor caution. Refrigerant work is EPA-certified tech only.
  3. Locate the parts: inspect the outdoor coil through the grille, clear plants and debris from around the unit, and check the outdoor fan motor and its capacitor in the control box and fan deck.
  4. Test: wash the coil, confirm the fan runs at full speed on a call, then have a technician measure discharge pressure and verify charge against the unit's published values; high pressure with a clean coil and good fan pinpoints overcharge, while normal pressure with trips condemns the switch circuit.
  5. End at the fix: correct the coil, fan or charge cause, restore power to clear the lockout, and run a full cooling call to confirm no repeat trip.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 29 / L29 code

Parts run $5–$35

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manufacturer documentation

Manual & model number

Find your model number on the outdoor unit's rating plate. It's the key to the right manual pages and the right parts.

Related Rheem Heat pump RP20 variable-speed heat pumps with Variable Speed Outdoor Control (VSODC) and EcoNet error codes

See all Rheem RP20 variable-speed heat pumps with Variable Speed Outdoor Control (VSODC) and EcoNet codes & guides →