Burnham Boiler Alpine (ALP) series, Sage2.2 control Soft Lockout 11

What this problem usually means

A soft lockout: ignition failure, meaning the flame failed after five tries to restart. The boiler tried repeatedly and could not establish or hold flame, and the listed causes run from simple gas supply problems to the electrode and gas valve. Air in a new gas line and low inlet pressure are the first things to rule out.

Likely causes

  1. No gas pressure to the boiler
  2. Gas pressure below the minimum value shown on the rating plate
  3. Gas line not completely purged of air
  4. Defective electrode
  5. Loose burner ground connection
  6. Defective ignition cable
  7. Defective gas valve
  8. Air-fuel mixture out of adjustment

How to fix it — step by step

  1. Record the lockout number and note whether the boiler was newly installed or the gas was recently off, which makes unpurged air likely.
  2. Safety: close the gas shutoff and switch the service switch off before opening the burner compartment. If you smell gas, stop and call the gas supplier.
  3. Locate the electrode and ignition cable at the burner, and the gas valve on the gas train, with the rating plate minimum gas pressure noted before testing.
  4. Test: check for gas pressure at the boiler and purge air from the line if it is new or was opened. Check for 24 Vac at the gas valve harness during a trial for ignition before condemning the valve: voltage present with no gas flow condemns the valve, while no voltage points back at the control or wiring.
  5. End at the fix: restore correct gas pressure and purge the line, tighten the burner ground, and replace a defective electrode, ignition cable or gas valve as the tests direct. Air-fuel mixture adjustment is factory-level work for a technician.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $100–$355

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.

Related Burnham Boiler Alpine (ALP) series, Sage2.2 control problems

See all Burnham Alpine (ALP) series, Sage2.2 control codes & guides →