Burnham Boiler Alpine (ALP) series, Sage2.2 control Soft Lockout 16
What this problem usually means
A soft lockout: the supply water temperature has risen too quickly. Heat is building in the boiler faster than the water can carry it away, which is the same low flow family of causes as a supply high limit trip. The boiler restarts once the condition clears.
Likely causes
- Inadequate boiler water flow
- Defective system or boiler circulator, or no flow in a loop
- Heating load far below the boiler minimum firing rate
- Control miswired so the boiler can run with no zones calling
How to fix it — step by step
- Record the lockout number and how quickly the supply temperature climbs on a firing attempt.
- Safety: switch the service switch off before working on circulators or control wiring.
- Locate the boiler and system circulators and confirm each one actually moves water when the boiler fires.
- Test: watch the supply temperature rise with a call for heat and all zones open. A slow, normal rise with proven flow means the earlier trip came from a no-call firing condition, which points at the control wiring. A fast rise with a zone calling confirms the flow problem.
- End at the fix: restore adequate boiler water flow, repair or replace a failed circulator, and correct any control wiring that lets the boiler operate when no zones are calling.
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Boiler circulator.
Parts that commonly fix it
- Boiler circulatorShop at Amazon
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.
Related Burnham Boiler Alpine (ALP) series, Sage2.2 control problems
- Soft Lockout 2
- Soft Lockout 3
- Soft Lockout 7
- Soft Lockout 8
- Soft Lockout 9
- Hard Lockout 12
- Hard Lockout 18
- Hard Lockout 19
- Hard Lockout 20
- Hard Lockout 23
- Hard Lockout 24
- Hard Lockout 25
See all Burnham Alpine (ALP) series, Sage2.2 control codes & guides →