Bosch Boiler Error Codes
Find your code in the list below. Each page explains what the code means, the most likely causes, step-by-step fixes you can do yourself, and the parts that commonly resolve it. 23 codes covered.
Finding your model number: it is on the rating plate on the boiler jacket, often behind the front panel.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
Buderus Logamax plus GB162 (UBA 3 display codes)
The UBA 3 control shows a main code plus a 3-digit subdisplay (for example 6A 227). The main code alone is not the fault - the GB162 reuses main codes across subdisplays, so read the pair together.
| Code | What it means | Check first | |
|---|---|---|---|
| 0Y 276 | Display code 0Y with subdisplay 276 is a blocking fault: the supply temperature sensor has measured a heating… | Supply temperature above 203 F (95 C) | › |
| 0Y 285 | Display code 0Y with subdisplay 285 is a blocking fault: the return temperature sensor has measured a return… | Return temperature above 203 F (95 C) | › |
| 1A 316 | Display code 1A with subdisplay 316 is a locking fault: the flue gas sensor temperature is too high. The… | Flue gas temperature too high | › |
| 1C 210 | Display code 1C with subdisplay 210 is a locking fault: the safety temperature switch has measured an… | Safety temperature switch open on high temperature | › |
| 2E 207 | Display code 2E with subdisplay 207 is a blocking fault: heating system water pressure is too low, under 3… | System water pressure under 3 PSI | › |
| 2F 260 | Display code 2F with subdisplay 260 is a blocking fault: the supply temperature sensor measured no heating… | No water temperature rise after burner start | › |
| 2L 266 | Display code 2L with subdisplay 266 is a locking fault: the pressure sensor failed to measure a pressure… | Pressure sensor failed to detect a pressure rise in four attempts | › |
| 2P 212 | Display code 2P with subdisplay 212 is a blocking fault: the supply temperature sensor measured a heating… | Supply temperature rising faster than 9 F per second | › |
| 2U 213 | Display code 2U with subdisplay 213 is a blocking fault: the temperature difference between the supply… | Supply-to-return difference over 90 F (50 C) | › |
| 3A 264 | Display code 3A with subdisplay 264 is a blocking fault: the fan unit tacho signal failed, or the fan unit… | Fan tacho signal lost during operation | › |
| 3C 217 | Display code 3C with subdisplay 217 is a locking fault: the fan unit is running irregularly while starting… | Fan running irregularly at startup | › |
| 3L 214 | Display code 3L with subdisplay 214 is a locking fault: the fan unit tacho signal or the fan main voltage was… | No fan tacho signal before ignition | › |
| 3P 216 | Display code 3P with subdisplay 216 is a locking fault: the fan unit is running too slowly. A fan that cannot… | Fan running too slowly | › |
| 3Y 215 | Display code 3Y with subdisplay 215 is a locking fault: the fan unit is running too fast. Overspeed means the… | Fan running too fast | › |
| 4A 218 | Display code 4A with subdisplay 218 is a locking fault: the supply temperature sensor measured a heating… | Supply temperature above 221 F (105 C) | › |
| 4C 224 | Display code 4C with subdisplay 224 is a locking fault: the safety temperature switch measured an excessively… | Safety temperature switch open on excess temperature | › |
| 4U 222 | Display code 4U with subdisplay 222 is a locking fault: the contacts of the supply temperature sensor have… | Supply temperature sensor contacts shorted | › |
| 4Y 223 | Display code 4Y with subdisplay 223 is a locking fault: the contacts of the supply temperature sensor are… | Supply temperature sensor contacts open | › |
| 6A 227 | Display code 6A with subdisplay 227 is the GB162 flame fault: insufficient flame activity (ionization… | Insufficient ionization current during ignition attempts | › |
| 6C 228 | Display code 6C with subdisplay 228 is a locking fault: flames (ionization current) were measured after a… | Flame signal present before the gas valve opened | › |
| 6L 229 | Display code 6L with subdisplay 229 is a blocking fault: insufficient flame activity (ionization current) was… | Flame signal lost during the run | › |
| 6P 269 | Display code 6P with subdisplay 269 is a locking fault: the glow ignitor was activated for more than 10… | Glow ignitor activated longer than 10 minutes | › |
| 9L 234 | Display code 9L with subdisplay 234 is a locking fault: the contacts of the gas valve are open. The control… | Gas valve contacts open | › |
Common questions
Why does my Buderus GB162 show two codes at once?
That is how the UBA 3 display works: a main code (like 6A) plus a 3-digit subdisplay (like 227). The service table keys each fault to the pair, because one main code covers several different faults told apart by the subdisplay.
Are the GB162 operating displays faults?
No. Displays like -H (heating mode), =H (hot water mode) and the 0A/0C/0E/0H startup states are normal operation in the same table; the fault rows are the ones the entries on this page cover.
Once you know the part you need, browse Bosch Boiler replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.