Bosch Boiler Buderus Logamax plus GB162 6L 229 Error Code

What the 6L 229 code means

Display code 6L with subdisplay 229 is a blocking fault: insufficient flame activity (ionization current) was measured during the burner run, after the flame had already been proven. The flame weakened or was lost mid-run and the boiler shut down and will retry. Repeated 6L faults usually end in a 6A lockout.

Likely causes

  1. Flame signal lost during the run
  2. Unstable gas pressure under load
  3. Fouled ionization electrode or burner
  4. Air/fuel ratio out of adjustment

How to fix it — step by step

  1. Record the code before resetting anything: write down the display exactly as shown (6L 229) and whether the boiler was in a heating call, a hot-water call, or idle when it appeared.
  2. Safety: turn the thermostat down, switch off power to the boiler at the service switch and breaker, and close the manual gas shutoff if you smell gas or see scorching. Do not open the burner compartment if you smell gas; leave and call the gas supplier.
  3. Locate the part: the ionization electrode and burner are behind the burner cover inside the front door; the gas valve and venturi are directly below the burner.
  4. Test: measure ionization current while the burner runs and watch whether it decays before the fault, and check dynamic gas pressure during firing. A current that fades with steady gas pressure condemns the electrode or burner condition; pressure that sags condemns the supply.
  5. End at the pinpoint: clean the burner and Ionization electrode, correct the gas supply or ratio fault, or replace the electrode as the measurements condemn. Technician work. → Shop the ionization electrode at Amazon

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 6L 229 code

Parts run $100–$355

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Bosch manual is on Bosch's support site — you'll need your model number.

Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.

Related Bosch Boiler Buderus Logamax plus GB162 error codes

See all Bosch Buderus Logamax plus GB162 codes & guides →