Bosch Boiler Buderus Logamax plus GB162 6A 227 Error Code
What the 6A 227 code means
Display code 6A with subdisplay 227 is the GB162 flame fault: insufficient flame activity (ionization current) was measured during ignition. On the first, second or third attempt it is a blocking fault; on the fourth attempt it becomes a locking fault that needs a reset. In plain terms, the burner lit weakly or not at all and the flame signal never proved.
Likely causes
- Insufficient ionization current during ignition attempts
- No gas supply or gas pressure under the rating-plate minimum
- Dirty or damaged ionization electrode
- Defective glow ignitor or gas valve
How to fix it — step by step
- Record the code before resetting anything: write down the display exactly as shown (6A 227) and whether the boiler was in a heating call, a hot-water call, or idle when it appeared.
- Safety: turn the thermostat down, switch off power to the boiler at the service switch and breaker, and close the manual gas shutoff if you smell gas or see scorching. Do not open the burner compartment if you smell gas; leave and call the gas supplier.
- Locate the part: the ionization electrode and glow ignitor are at the burner, reached through the burner cover area after opening the front door; the gas valve is below the burner with the venturi.
- Test: confirm gas supply pressure, watch the ignitor glow through the sight glass, and measure the ionization current per the service manual. Good gas and glow with low ionization current condemns the electrode or its ground; no glow condemns the ignitor circuit.
- End at the pinpoint: clean or replace the Ionization electrode, replace the Glow ignitor, or repair the gas supply/valve fault, whichever the checks condemn, then reset. Gas-side work is technician work. → Shop the ionization electrode at Amazon → Shop the glow ignitor at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Ionization electrode.
Shop the Ionization electrode at Amazon
Also tied to this fault: Glow ignitor - Shop at Amazon; Gas valve - Shop at Amazon
Parts that commonly fix the 6A 227 code
- Ionization electrodeShop at Amazon
- Glow ignitorShop at Amazon
- Gas valve$100–$355Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Bosch manual is on Bosch's support site — you'll need your model number.
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.