Bosch Boiler Buderus Logamax plus GB162 3P 216 Error Code

What the 3P 216 code means

Display code 3P with subdisplay 216 is a locking fault: the fan unit is running too slowly. A fan that cannot reach speed cannot move enough combustion air or flue gas, so the boiler locks out. Blocked intake or flue, a failing fan, and a bad speed signal are the suspects.

Likely causes

  1. Fan running too slowly
  2. Blocked air intake or flue passage
  3. Failing fan motor

How to fix it — step by step

  1. Record the code before resetting anything: write down the display exactly as shown (3P 216) and whether the boiler was in a heating call, a hot-water call, or idle when it appeared.
  2. Safety: turn the thermostat down, switch off power to the boiler at the service switch and breaker, and close the manual gas shutoff if you smell gas or see scorching. Do not open the burner compartment if you smell gas; leave and call the gas supplier.
  3. Locate the part: the fan unit is above the burner; the air intake connection and flue gas connection are at the top of the boiler.
  4. Test: inspect the intake and flue terminations and passages for blockage first, then watch the fan on a start attempt. A clear air path with a fan that still lags condemns the fan unit.
  5. End at the pinpoint: clear the blockage found, or replace the Fan unit if the air path is proven clear, then reset. Technician work. → Shop the fan at Amazon

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 3P 216 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Bosch manual is on Bosch's support site — you'll need your model number.

Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.

Related Bosch Boiler Buderus Logamax plus GB162 error codes

See all Bosch Buderus Logamax plus GB162 codes & guides →