Bosch Boiler Buderus Logamax plus GB162 6C 228 Error Code
What the 6C 228 code means
Display code 6C with subdisplay 228 is a locking fault: flames (ionization current) were measured after a heat demand occurred but before the gas valve opened. The control saw a flame signal at a time when no flame should exist. That can be a leaking gas valve, a shorted ionization circuit, or a control fault, and the boiler locks out for safety.
Likely causes
- Flame signal present before the gas valve opened
- Gas valve leaking through
- Ionization electrode shorted to ground
- Defective UBA 3 control
How to fix it — step by step
- Record the code before resetting anything: write down the display exactly as shown (6C 228) and whether the boiler was in a heating call, a hot-water call, or idle when it appeared.
- Safety: turn the thermostat down, switch off power to the boiler at the service switch and breaker, and close the manual gas shutoff if you smell gas or see scorching. Do not open the burner compartment if you smell gas; leave and call the gas supplier.
- Locate the part: the ionization electrode is at the burner; the gas valve is below the burner; the electrode cable runs to the UBA 3 control.
- Test: with the boiler off, check whether a real flame is present at the burner (a leaking valve) versus a false signal with no flame (electrode short or control). Inspect the electrode and cable for contact with ground or burner metal.
- End at the pinpoint: replace the Gas valve if it passes gas when closed; clear the electrode short or replace the Ionization electrode if the signal is false; if both prove good, the pinpoint is the UBA 3 control. Technician work only. → Shop the ionization electrode at Amazon → Shop the uba 3 control at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Gas valve.
Also tied to this fault: Ionization electrode - Shop at Amazon; UBA 3 control - Shop at Amazon
Parts that commonly fix the 6C 228 code
- Gas valve$100–$355Shop at Amazon
- Ionization electrodeShop at Amazon
- UBA 3 controlShop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Bosch manual is on Bosch's support site — you'll need your model number.
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.