Bosch Boiler Buderus Logamax plus GB162 2P 212 Error Code

What the 2P 212 code means

Display code 2P with subdisplay 212 is a blocking fault: the supply temperature sensor measured a heating water temperature increase of more than 9 F per second (5 C per second). Water heating that fast is moving far too slowly past the sensor. The boiler blocks to protect the heat exchanger.

Likely causes

  1. Supply temperature rising faster than 9 F per second
  2. Very low water flow through the boiler
  3. Air locked or valved-off boiler loop

How to fix it — step by step

  1. Record the code before resetting anything: write down the display exactly as shown (2P 212) and whether the boiler was in a heating call, a hot-water call, or idle when it appeared.
  2. Safety: turn the thermostat down, switch off power to the boiler at the service switch and breaker, and close the manual gas shutoff if you smell gas or see scorching. Do not open the burner compartment if you smell gas; leave and call the gas supplier.
  3. Locate the part: start at the circulator in the pump group and the isolating valves on the supply and return connections below the boiler.
  4. Test: verify the circulator runs, the isolating valves are fully open, and the loop is bled of air. Normal flow restored and a code that still sets on every start points to the supply sensor misreading.
  5. End at the pinpoint: fix the flow fault found (Circulator, valves, air) and restart; if flow is proven strong, replace the supply Temperature sensor. Technician work.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 2P 212 code

Parts run $25–$80

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Bosch manual is on Bosch's support site — you'll need your model number.

Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.

Related Bosch Boiler Buderus Logamax plus GB162 error codes

See all Bosch Buderus Logamax plus GB162 codes & guides →