What the 4Y 223 code means

Display code 4Y with subdisplay 223 is a locking fault: the contacts of the supply temperature sensor are open. The control has lost the supply temperature signal entirely and locks out. An unplugged connector, a broken cable, or a failed-open sensor are the usual causes.

Likely causes

  1. Supply temperature sensor contacts open
  2. Sensor connector unplugged or corroded
  3. Broken sensor cable

How to fix it — step by step

  1. Record the code before resetting anything: write down the display exactly as shown (4Y 223) and whether the boiler was in a heating call, a hot-water call, or idle when it appeared.
  2. Safety: turn the thermostat down, switch off power to the boiler at the service switch and breaker, and close the manual gas shutoff if you smell gas or see scorching. Do not open the burner compartment if you smell gas; leave and call the gas supplier.
  3. Locate the part: the supply temperature sensor at the heat exchanger outlet; check its plug first, then trace the cable to the control.
  4. Test: reseat the connector, then measure sensor resistance against the manual's table. Infinite resistance at the sensor pins condemns the sensor; a good sensor reading with an open loop condemns the cable.
  5. End at the pinpoint: replace the Temperature sensor or repair the cable as the resistance test directs, then reset the lockout. Technician work.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 4Y 223 code

Parts run $25–$80
  • Temperature sensor$25–$80Shop at Amazon
  • Tools for this job, if you need them$15–$65

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Bosch manual is on Bosch's support site — you'll need your model number.

Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.

Related Bosch Boiler Buderus Logamax plus GB162 error codes