Bosch Boiler Buderus Logamax plus GB162 3Y 215 Error Code

What the 3Y 215 code means

Display code 3Y with subdisplay 215 is a locking fault: the fan unit is running too fast. Overspeed means the control has lost proper command of the fan or the speed signal is wrong, and the boiler locks out rather than fire with uncontrolled combustion air. The fan and its tacho circuit are the focus.

Likely causes

  1. Fan running too fast
  2. Faulty fan tacho signal
  3. Fan control fault in the UBA 3

How to fix it — step by step

  1. Record the code before resetting anything: write down the display exactly as shown (3Y 215) and whether the boiler was in a heating call, a hot-water call, or idle when it appeared.
  2. Safety: turn the thermostat down, switch off power to the boiler at the service switch and breaker, and close the manual gas shutoff if you smell gas or see scorching. Do not open the burner compartment if you smell gas; leave and call the gas supplier.
  3. Locate the part: the fan unit above the burner and its tacho cable to the UBA 3 control, both inside the front door.
  4. Test: inspect the tacho cable for damage or poor connection, then observe a startup. A fan racing from the moment power is applied, with a sound tacho cable, points to the fan's own drive or the control. → Shop the fan at Amazon
  5. End at the pinpoint: repair the tacho wiring if condemned; otherwise replace the Fan unit, and if a new fan still overspeeds, the pinpoint is the UBA 3 control. Technician work.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 3Y 215 code

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Bosch manual is on Bosch's support site — you'll need your model number.

Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.

Related Bosch Boiler Buderus Logamax plus GB162 error codes

See all Bosch Buderus Logamax plus GB162 codes & guides →