Bosch Boiler Buderus Logamax plus GB162 1C 210 Error Code
What the 1C 210 code means
Display code 1C with subdisplay 210 is a locking fault: the safety temperature switch has measured an excessively high temperature and opened, or there is no connection between contacts 50 and 78 of the UBA 3 mounting base. The boiler will not run until the switch circuit is restored and the lockout is reset.
Likely causes
- Safety temperature switch open on high temperature
- No connection between UBA 3 contacts 50 and 78
- Overheating from low water flow
How to fix it — step by step
- Record the code before resetting anything: write down the display exactly as shown (1C 210) and whether the boiler was in a heating call, a hot-water call, or idle when it appeared.
- Safety: turn the thermostat down, switch off power to the boiler at the service switch and breaker, and close the manual gas shutoff if you smell gas or see scorching. Do not open the burner compartment if you smell gas; leave and call the gas supplier.
- Locate the part: the safety temperature switch is on the flue/heat-exchanger area inside the boiler; its wiring lands on the UBA 3 burner control mounting base at the left side of the boiler.
- Test: with power off, check continuity through the safety switch and the harness to contacts 50 and 78. An open switch on a cool boiler is a failed switch; a closed switch with an open harness is a wiring fault; a switch that opened hot means find the overheating cause first.
- End at the pinpoint: replace the safety Temperature sensor/switch or repair the harness as the continuity test condemns, correct any low-flow cause, then reset. Technician work. → Shop the temperature sensor at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Temperature sensor.
Shop the Temperature sensor at Amazon
Also tied to this fault: UBA 3 control - Shop at Amazon
Parts that commonly fix the 1C 210 code
- Temperature sensor$25–$80Shop at Amazon
- UBA 3 controlShop at Amazon
- Tools for this job, if you need them$15–$65
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Bosch manual is on Bosch's support site — you'll need your model number.
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.