What the 4U 222 code means

Display code 4U with subdisplay 222 is a locking fault: the contacts of the supply temperature sensor have shorted. The control is reading an impossible supply temperature and locks out rather than run blind. The sensor or its cable is shorted.

Likely causes

  1. Supply temperature sensor contacts shorted
  2. Sensor cable shorted or pinched
  3. Water ingress at the sensor connection

How to fix it — step by step

  1. Record the code before resetting anything: write down the display exactly as shown (4U 222) and whether the boiler was in a heating call, a hot-water call, or idle when it appeared.
  2. Safety: turn the thermostat down, switch off power to the boiler at the service switch and breaker, and close the manual gas shutoff if you smell gas or see scorching. Do not open the burner compartment if you smell gas; leave and call the gas supplier.
  3. Locate the part: the supply temperature sensor is at the heat exchanger outlet inside the front door; trace its cable back to the control for pinch or damage points.
  4. Test: disconnect the sensor and measure its resistance against the manual's sensor resistance table for the water temperature. A sensor reading near zero, or a cable that stays shorted with the sensor unplugged, separates sensor fault from harness fault. → Shop the temperature sensor at Amazon
  5. End at the pinpoint: replace the Temperature sensor if it is shorted, or repair the cable if the short is in the harness, then reset. Technician work.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix the 4U 222 code

Parts run $25–$80

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Working on a specific model? The official Bosch manual is on Bosch's support site — you'll need your model number.

Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.

Related Bosch Boiler Buderus Logamax plus GB162 error codes

See all Bosch Buderus Logamax plus GB162 codes & guides →