Bosch Boiler Buderus Logamax plus GB162 6P 269 Error Code
What the 6P 269 code means
Display code 6P with subdisplay 269 is a locking fault: the glow ignitor was activated for more than 10 minutes. The control kept the ignitor energized far beyond a normal ignition sequence, which means ignition kept failing or the control kept retrying. The boiler locks out to protect the ignitor and the burner.
Likely causes
- Glow ignitor activated longer than 10 minutes
- Repeated failed ignition attempts
- Defective glow ignitor
- No gas supply reaching the burner
How to fix it — step by step
- Record the code before resetting anything: write down the display exactly as shown (6P 269) and whether the boiler was in a heating call, a hot-water call, or idle when it appeared.
- Safety: turn the thermostat down, switch off power to the boiler at the service switch and breaker, and close the manual gas shutoff if you smell gas or see scorching. Do not open the burner compartment if you smell gas; leave and call the gas supplier.
- Locate the part: the glow ignitor is at the burner beside the ionization electrode, visible at the sight glass after opening the front door.
- Test: watch a start attempt through the sight glass. An ignitor that never glows condemns the ignitor or its supply; a strong glow with no flame sends the check to gas supply and the gas valve, the same path as a 6A fault.
- End at the pinpoint: replace the Glow ignitor if it does not glow or is cracked; otherwise fix the gas-side cause found, then reset. Technician work. → Shop the glow ignitor at Amazon
Did that fix it?
Worked through the steps? Say where you landed - it pinpoints what to do next.
Good - you're done. If it comes back, the causes at the top of this page are where to look first.
This fault usually needs a technician - but this is the part they would test first.
Then the likely broken part is the Glow ignitor.
Shop the Glow ignitor at Amazon
Also tied to this fault: Gas valve - Shop at Amazon
Parts that commonly fix the 6P 269 code
- Glow ignitorShop at Amazon
- Gas valve$100–$355Shop at Amazon
Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.
What fixed yours?
Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.
Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.
Manual & model number
Working on a specific model? The official Bosch manual is on Bosch's support site — you'll need your model number.
Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.