Burnham Boiler Alpine (ALP) series, Sage2.2 control Hard Lockout 6

What this problem usually means

A hard lockout needing a manual reset: the flue gas (stack) sensor detected temperatures in excess of 204 degrees F (95.6 degrees C). Flue gas that hot on a condensing boiler means the heat exchanger is not transferring heat into the water, most often because it needs cleaning. This one should not just be reset and watched.

Likely causes

  1. Heat exchanger needs to be cleaned
  2. Boiler over-fired
  3. Air-fuel mixture out of adjustment

How to fix it — step by step

  1. Record the lockout number and the stack temperature reading before resetting.
  2. Safety: switch the service switch off, close the gas shutoff, and let the boiler cool before opening the heat exchanger compartment.
  3. Locate the heat exchanger through the front access and inspect its passages for scale, debris and condensate residue buildup.
  4. Test: a fouled heat exchanger found on inspection explains the code directly. A clean exchanger with the code returning means the boiler is over-fired or the air-fuel mixture is off, both of which are proven with a combustion analyzer at the flue.
  5. End at the fix: clean the heat exchanger if it is fouled. Over-firing and air-fuel mixture correction are factory-level adjustments for a technician with an analyzer. Reset manually after the cause is corrected.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

Parts run $25–$80

Typical ranges, checked Nov 2026. Your model’s exact part can land outside them.

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.

Manual & model number

Find your model number on the rating plate on the boiler jacket, often behind the front panel. It's the key to the right manual pages and the right parts.

Related Burnham Boiler Alpine (ALP) series, Sage2.2 control problems

See all Burnham Alpine (ALP) series, Sage2.2 control codes & guides →