American Standard Heat pump Common Problems
Find your problem in the list below. Each page explains the most likely causes, step-by-step checks you can do yourself, when to call a pro, and the parts that commonly resolve it. 17 problems covered.
Not sure of the code? Tap along with it
If your American Standard Heat pump blinks or beeps a pattern instead of showing a code, tap the button in time with each blink or beep. A pause longer than a second and a half starts a new group - we will match the rhythm to a code.
Your taps: -
Finding your model number: it is on the outdoor unit's rating plate.
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
EEV board flash codes
Flash counts read on the electronic expansion valve (EEV) control board.
| Problem | What it means | Check first | |
|---|---|---|---|
| EEV board 6 flashes | Read on the red Fault LED of the Electronic Expansion Valve control board in this American Standard heat… | EEV stuck mechanically | › |
| EEV board 9 flashes | Read on the red Fault LED of the Electronic Expansion Valve control board in this American Standard heat… | Indoor TXV stuck open | › |
AccuLink (alert codes + Charge Assist LEDs)
Alert codes show at the AccuLink control; the Charge Assist LED flash counts for charging are listed as their own family.
| Problem | What it means | Check first | |
|---|---|---|---|
| 1 flash | Read on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 91. The… | Communicating data wiring broken, disconnected or shorted | › |
| 10 flashes | Read on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 102. The… | Y1 and Y2 demand wires crossed, mislanded or shorted in the field wiring | › |
| 11 flashes | Read on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 67. The… | Liquid temperature sensor open or shorted | › |
| 12 flashes | Read on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 113. The… | Liquid pressure sensor (transducer) open or shorted or out of range | › |
| 13 flashes | Read on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 67. The… | External outdoor temperature sensor shorted | › |
| 14 flashes | Read on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 114. The… | Personality Module missing, unseated or disturbed during service | › |
| 17 flashes | Read on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 80. The… | Outdoor fan motor failure in cooling | › |
| 18 flashes | Read on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 18. The… | No 24V supply reaching the outdoor control - tripped breaker, blown indoor fuse or | › |
| 2 flashes | Read on the red Fault LED of the AccuLink outdoor control. The Summary of Alert Code and Charge Assist LEDs… | Coil or ambient temperature sensor giving the defrost control bad information | › |
| 3 flashes | Read on the red Fault LED of the AccuLink outdoor control. The Summary of Alert Code and Charge Assist LEDs… | Coil temperature sensor not tracking the defrost temperature rise correctly | › |
| 4 flashes | Read on the red Fault LED of the AccuLink outdoor control. The Summary of Alert Code and Charge Assist LEDs… | Multiple defrost sensor faults - ambient and coil sensors both unreliable | › |
| 5 flashes | Read on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 67. The… | Ambient temperature sensor open or shorted | › |
| 6 flashes | Read on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 67. The… | Coil temperature sensor open or shorted | › |
| 7 flashes | Read on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 79. The… | Low refrigerant charge from a leak | › |
| ERR 90 | Shown in the Summary of Alert Code and Charge Assist LEDs in the American Standard Service Facts for this… | Damaged or loose communicating wiring between indoor unit, outdoor unit and comfort | › |
Common questions
What does alert code 90 mean on an American Standard heat pump?
Excessive communication errors on the AccuLink system: the Service Facts summary pairs alert 90 with loss of the heat/cool demand signal between the communicating components.
Once you know the part you need, browse American Standard Heat pump replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.