American Standard Heat pump Common Problems

Find your problem in the list below. Each page explains the most likely causes, step-by-step checks you can do yourself, when to call a pro, and the parts that commonly resolve it. 17 problems covered.

Not sure of the code? Tap along with it

If your American Standard Heat pump blinks or beeps a pattern instead of showing a code, tap the button in time with each blink or beep. A pause longer than a second and a half starts a new group - we will match the rhythm to a code.

Your taps: -

Finding your model number: it is on the outdoor unit's rating plate.

Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.

EEV board flash codes

Flash counts read on the electronic expansion valve (EEV) control board.

ProblemWhat it meansCheck first
EEV board 6 flashesRead on the red Fault LED of the Electronic Expansion Valve control board in this American Standard heat…EEV stuck mechanically›
EEV board 9 flashesRead on the red Fault LED of the Electronic Expansion Valve control board in this American Standard heat…Indoor TXV stuck open›

Alert codes show at the AccuLink control; the Charge Assist LED flash counts for charging are listed as their own family.

ProblemWhat it meansCheck first
1 flashRead on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 91. The…Communicating data wiring broken, disconnected or shorted›
10 flashesRead on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 102. The…Y1 and Y2 demand wires crossed, mislanded or shorted in the field wiring›
11 flashesRead on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 67. The…Liquid temperature sensor open or shorted›
12 flashesRead on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 113. The…Liquid pressure sensor (transducer) open or shorted or out of range›
13 flashesRead on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 67. The…External outdoor temperature sensor shorted›
14 flashesRead on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 114. The…Personality Module missing, unseated or disturbed during service›
17 flashesRead on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 80. The…Outdoor fan motor failure in cooling›
18 flashesRead on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 18. The…No 24V supply reaching the outdoor control - tripped breaker, blown indoor fuse or›
2 flashesRead on the red Fault LED of the AccuLink outdoor control. The Summary of Alert Code and Charge Assist LEDs…Coil or ambient temperature sensor giving the defrost control bad information›
3 flashesRead on the red Fault LED of the AccuLink outdoor control. The Summary of Alert Code and Charge Assist LEDs…Coil temperature sensor not tracking the defrost temperature rise correctly›
4 flashesRead on the red Fault LED of the AccuLink outdoor control. The Summary of Alert Code and Charge Assist LEDs…Multiple defrost sensor faults - ambient and coil sensors both unreliable›
5 flashesRead on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 67. The…Ambient temperature sensor open or shorted›
6 flashesRead on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 67. The…Coil temperature sensor open or shorted›
7 flashesRead on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 79. The…Low refrigerant charge from a leak›
ERR 90Shown in the Summary of Alert Code and Charge Assist LEDs in the American Standard Service Facts for this…Damaged or loose communicating wiring between indoor unit, outdoor unit and comfort›

Common questions

What does alert code 90 mean on an American Standard heat pump?
Excessive communication errors on the AccuLink system: the Service Facts summary pairs alert 90 with loss of the heat/cool demand signal between the communicating components.

Looking for a part?

Once you know the part you need, browse American Standard Heat pump replacement parts → The parts shelves are organized by brand, with the parts that actually fix these codes.