American Standard 4A7A6048C1000B heat pump with AccuLink and Charge Assist Common Problems
Find your problem in the list below. Each page explains the most likely causes, step-by-step checks you can do yourself, when to call a pro, and the parts that commonly resolve it. 15 problems covered.
Not sure of the code? Tap along with it
If your American Standard Heat pump blinks or beeps a pattern instead of showing a code, tap the button in time with each blink or beep. A pause longer than a second and a half starts a new group - we will match the rhythm to a code.
Your taps: -
Tap any code for its full fix — causes, step-by-step checks, and the parts that commonly fix it.
| Problem | What it means | Check first | |
|---|---|---|---|
| 1 flash | Read on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 91. The… | Communicating data wiring broken, disconnected or shorted | › |
| 10 flashes | Read on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 102. The… | Y1 and Y2 demand wires crossed, mislanded or shorted in the field wiring | › |
| 11 flashes | Read on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 67. The… | Liquid temperature sensor open or shorted | › |
| 12 flashes | Read on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 113. The… | Liquid pressure sensor (transducer) open or shorted or out of range | › |
| 13 flashes | Read on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 67. The… | External outdoor temperature sensor shorted | › |
| 14 flashes | Read on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 114. The… | Personality Module missing, unseated or disturbed during service | › |
| 17 flashes | Read on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 80. The… | Outdoor fan motor failure in cooling | › |
| 18 flashes | Read on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 18. The… | No 24V supply reaching the outdoor control - tripped breaker, blown indoor fuse or | › |
| 2 flashes | Read on the red Fault LED of the AccuLink outdoor control. The Summary of Alert Code and Charge Assist LEDs… | Coil or ambient temperature sensor giving the defrost control bad information | › |
| 3 flashes | Read on the red Fault LED of the AccuLink outdoor control. The Summary of Alert Code and Charge Assist LEDs… | Coil temperature sensor not tracking the defrost temperature rise correctly | › |
| 4 flashes | Read on the red Fault LED of the AccuLink outdoor control. The Summary of Alert Code and Charge Assist LEDs… | Multiple defrost sensor faults - ambient and coil sensors both unreliable | › |
| 5 flashes | Read on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 67. The… | Ambient temperature sensor open or shorted | › |
| 6 flashes | Read on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 67. The… | Coil temperature sensor open or shorted | › |
| 7 flashes | Read on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 79. The… | Low refrigerant charge from a leak | › |
| ERR 90 | Shown in the Summary of Alert Code and Charge Assist LEDs in the American Standard Service Facts for this… | Damaged or loose communicating wiring between indoor unit, outdoor unit and comfort | › |