American Standard Heat pump 4A7A6048C1000B heat pump with AccuLink and Charge Assist 1 flash

What it should look like on your machine

then it repeats

1 flash - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Read on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 91. The Summary of Alert Code and Charge Assist LEDs in the American Standard Service Facts lists one flash for loss of the heat/cool demand message and loss of the Bit Master clock signal. In other words the outdoor unit has stopped hearing valid demand or timing messages from the communicating system. It matters because without demand messages the outdoor unit cannot stage the compressor correctly, so heating and cooling calls go unanswered.

Likely causes

  1. Communicating data wiring broken, disconnected or shorted
  2. Loss of the Bit Master clock signal from the indoor control
  3. Loose low-voltage connections at the outdoor control board
  4. Failed indoor or outdoor control board

How to fix it — step by step

  1. Record the code before cycling power: count one flash on the outdoor Fault LED and record ERR 91 at the comfort control before cycling power. Power-cycling can clear, change or recount the fault, so note the display, operating mode and outdoor temperature first.
  2. Safety: turn the system off, open the outdoor disconnect and breaker, verify with a meter that the unit is dead before touching wiring, and stay clear of the run capacitor terminals - a capacitor can hold a shock charge with power off.
  3. Locate the part: inspect the communicating wiring at the outdoor control board inside the outdoor control box and trace it toward the indoor unit
  4. Test: check for a present, stable low-voltage supply at the outdoor board and reseat its communicating connectors; the Service Facts clears these faults by cycling power to the outdoor unit, so note whether one flash returns immediately, which points to a hard wiring or board failure
  5. End point: repair damaged communicating wiring. If wiring and power are good and the demand and clock messages are still lost, a technician should determine whether the indoor or outdoor control board has failed. Any work that opens the sealed refrigerant circuit, adjusts charge, or replaces a refrigerant pressure device is EPA-certified technician work only.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.