American Standard Heat pump 4A7A6048C1000B heat pump with AccuLink and Charge Assist 10 flashes

What it should look like on your machine

then it repeats

10 flashes - then the pattern repeats. Count along with your machine and compare.

What this problem usually means

Read on the red Fault LED of the AccuLink outdoor control, and shown at the comfort control as ERR 102. The Summary of Alert Code and Charge Assist LEDs in the American Standard Service Facts lists ten flashes as 'Y2 without Y1 - Miswire': the outdoor control is seeing a second-stage compressor request without a first-stage request, a wiring or configuration error rather than a failed refrigeration component. It matters because staging logic expects Y1 before Y2; running on a miswired demand can short-cycle or mis-stage the two-stage compressor and will keep faulting until the demand wiring is corrected.

Likely causes

  1. Y1 and Y2 demand wires crossed, mislanded or shorted in the field wiring
  2. Indoor control or thermostat sending second stage without first stage
  3. Damaged low-voltage cable between indoor and outdoor units
  4. Incorrect 24V conversion or accessory wiring on units coupled to 24V indoor controls

How to fix it — step by step

  1. Record the code before cycling power: count ten flashes and record ERR 102 before touching the wiring. Power-cycling can clear, change or recount the fault, so note the display, operating mode and outdoor temperature first.
  2. Safety: turn the system off, open the outdoor disconnect and breaker, verify with a meter that the unit is dead before touching wiring, and stay clear of the run capacitor terminals - a capacitor can hold a shock charge with power off.
  3. Locate the part: with power off, compare the low-voltage connections at the outdoor control board terminal by terminal with the wiring diagram in the Service Facts, then check the indoor end of the same cable
  4. Test: confirm Y1 is landed and continuous and that Y2 cannot be energised alone; a meter check for voltage on Y2 with no call on Y1, done live only by someone qualified, confirms the miswire the code describes
  5. End point: correct the field wiring to the diagram - that is the fix the code calls for. If the wiring is provably correct and Y2 still appears alone, the indoor control sending the demand is faulty and needs a technician. Any work that opens the sealed refrigerant circuit, adjusts charge, or replaces a refrigerant pressure device is EPA-certified technician work only.

Did that fix it?

Worked through the steps? Say where you landed - it pinpoints what to do next.

Parts that commonly fix it

What fixed yours?

Fixed this on your machine? Tap what did it - reports from owners set the percentages on this page.

Source: manufacturer / repair documentation. Codes can vary by model — confirm against your manual.